We appreciate the trust and confidence you have placed in us through the purchase of this pool pump. We strive to continually create quality
pool products. Visit us online to see our full line of products available. Thank you!
OWNER’S MANUAL
DV FLO PUMP APEX SERIES
Questions, problems, missing parts? Before returning to the store,
call Customer Service
8 a.m. - 6 p.m., EST, Monday - Friday
1-877-278-2797
ECOAQUAPRO.COM

Questions and Answers

  • D
    doris45Aug 4, 2025
    What to do if Aqua PRO DV FLO Water Pump failure to pump, reduced capacity or discharge pressure suction leaks/lost prime?
    • D
      Darlene OwenAug 4, 2025
      If your Aqua PRO Water Pump is experiencing a failure to pump, reduced capacity, discharge pressure, suction leaks, or has lost its prime, ensure that the pump body and basket body are full of water to prime the pump. Also, check for any leaks in the suction piping and ensure the suction inlet is well below the water level to prevent the pump from sucking air. You may also need to lower the pump closer to the water source or install a check valve in the suction line.
  • J
    Jacob FloydAug 11, 2025
    What to do if Aqua PRO DV FLO Water Pump fails to pump due to electrical issues?
    • N
      ngriffinAug 12, 2025
      If your Aqua PRO Water Pump is not pumping due to electrical issues, there are several things you can check: * If the pump is running too slowly, check the voltage at the motor terminals and at the meter while the pump is running. If the voltage is low, refer to the wiring instructions or consult your power company. Also, check for loose connections. * If the pump is too hot, check the line voltage. If it's less than 90% or more than 110% of the rated voltage, consult a licensed electrician. * Ensure adequate ventilation and reduce the ambient temperature around the pump. * Tighten any loose connections.
  • M
    Matthew BowmanAug 20, 2025
    How to fix Aqua PRO DV FLO Water Pump failure to pump due to clogged pipe/trap/impeller or worn impeller?
    • Y
      Yolanda RiosAug 20, 2025
      If your Aqua PRO Water Pump isn't pumping because of a clogged pipe, trap, or impeller, you should first check if the suction trap is clogged. If it is, clean the trap and the strainer. Next, check the impeller for clogging. Also, the impeller and diffuser may be worn, in this case order replacement parts by calling 1-888-658-1594. Finally, the pump may be trying to push too high a column of water, if so, a “higher head” pump is needed. Call 1-888-658-1594.
  • A
    Angela MooreAug 27, 2025
    Why is Aqua PRO Water Pump leaking around the motor?
    • C
      Carl ConnerAug 27, 2025
      If your Aqua PRO Water Pump is leaking around the motor, it is likely due to a mechanical seal failure. To prevent further damage to other components and reduce the risk of electric shock, take the pump out of service and replace the seal immediately.

Summary

Safety Information

Safety Guidelines

Highlights the importance of understanding safety information for proper use and problem prevention.

Electrical Hazards

Importance of qualified electricians for grounding and GFCI protection.

Installation

Pump Plumbing

Advises on pipe sizing, routing, support, and slope for optimal pump performance.

Pool Pump Suction Requirements

Critical safety warning about pump suction hazards and entrapment.

Entrapment Protection

Emphasizes designing suction to eliminate entrapment or hair entanglement.

Electrical

Ground Fault Circuit Interrupter (GFCI)

Requirement for GFCI protection and troubleshooting GFCI tripping.

Grounding;Bonding

Procedures for grounding and bonding the motor and pool equipment per code.

Wiring

Guidance on permanent connection, circuit breaker sizing, and GFCI installation.

Troubleshooting

Failure to Pump: Reduced Capacity or Discharge Pressure

Addresses issues like lost prime, suction leaks, and low pressure.

Failure to Pump: Clogged Pipe;Trap;Impeller, Worn Impeller

Diagnoses problems related to blockages or worn internal parts.

Failure to Pump: Electrical

Covers electrical issues such as slow motor speed, overheating, and voltage problems.

Warranty Information

Limited Warranty Details

Outlines the terms, coverage, exclusions, and duration of the limited warranty.