Why is there low pressure at the Aqua Systems Water System dispensing faucet?
- AAndrea ButlerAug 4, 2025
If you're experiencing low pressure at the dispensing faucet of your Aqua Systems Water System, it could be due to several reasons. A plugged activated carbon post filter can restrict water flow, so replace the post filter. If the air precharge in the holding tank is too low, empty the water and adjust the air pressure to 5–7 psig (35–48 kPa). Ensure the holding tank valve is fully open. The dispensing faucet itself might be faulty, requiring repair or replacement. If there's been heavy water use, the holding tank may be depleted; allow it to refill, or consider adding a second holding tank to increase storage capacity. Also, consider that low water production can cause low pressure; refer to the 'Low Quantity of Product Water from Holding Tank' section for solutions.