NOTPACAQX - ind S – 0315
12/41
TECHNICAL SPECIFICATIONS
Model
104274 104275 104276 105417 105418 104279
Operating range –
water (°C)
+5°to +35° +5°to +35° +5°to +35° +5°to +35° +5°to +35° +5°to +35°
Operating range – air
(°C)
+0°to +43° +0°to +43° +0°to +43° +0°to +43° +0°to +43° +0°to +43°
(kW)
(air 26°C, water
26°C)
10 13.5 17.5 25 25 33
(air 26°C, water
26°C)
6,6 7 6,7 6,9 6,9 6,8
(kW)
(air 15°C, water
26°C)
6.6 9.9 11.4 16.0 16.0 22.2
(air 15°C, water
26°C)
4,64 4,78 4,68 4,51 4,60 5.16
(kW)
(air 35°C, water
28°C)
6 8 10 15 15 20
m3 (with insulated
pool cover)**
30~50 40~70 60~90 75~120 75~120 110~150
flow rate (m³/h)
4-6 5-7 6.5-8.5 7-9 7-9 10-12
Nominal power (kW)
Fan direction
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
10m***
33.8 37.7 40.4 41.9 41.9 41.5
dB(A)
61.8 65.7 68.4 69.8 69.8 69.5
weight (kg)
55/ 63 70/ 80 72 / 82 105/ 117 105 / 117 123/ 138
*
COP : Coefficient of performance
**
Solar Cover when not bathing, use mid May-mid September, water temp 26 ° C, filtration mini 8h/day,
24h/24 to temperature setting, basin located in the department 13, 20m altitude (non-exhaustive criteria).
We recommend that you verify with a thermal study the choice of model.
*** :
Noise level is the acoustic value perceived by the human ear and measured by the SPL meter. It
depends on the installation environment and the distance at which the measure is made.