NOTPACAQX - ind S – 0315
12/41
TECHNICAL SPECIFICATIONS
Model
104274 104275 104276 105417 105418 104279
Operating range –
water (°C)
+5°to +35° +5°to +35° +5°to +35° +5°to +35° +5°to +35° +5°to +35°
Operating range – air
(°C)
+0°to +43° +0°to +43° +0°to +43° +0°to +43° +0°to +43° +0°to +43°
Heating capacity
(kW)
(air 26°C, water
26°C)
10 13.5 17.5 25 25 33
COP*
(air 26°C, water
26°C)
6,6 7 6,7 6,9 6,9 6,8
Heating capacity
(kW)
(air 15°C, water
26°C)
6.6 9.9 11.4 16.0 16.0 22.2
COP*
(air 15°C, water
26°C)
4,64 4,78 4,68 4,51 4,60 5.16
Cooling capacity
(kW)
(air 35°C, water
28°C)
6 8 10 15 15 20
COP*
4
4
3,
8
4
.2
4.2
4
Advised Pool volume
m3 (with insulated
pool cover)**
30~50 40~70 60~90 75~120 75~120 110~150
Recommended water
flow rate (m³/h)
4-6 5-7 6.5-8.5 7-9 7-9 10-12
Nominal power (kW)
1,
4
2
,
1
2,
4
3,
5
3,
5
4,
3
Electric power supply
2
3
0V
1Ph/50Hz
2
3
0V
1Ph/50Hz
2
3
0V
1Ph/50Hz
2
3
0V
1Ph/50Hz
400
3Ph/50Hz
40
0V
3Ph/50Hz
Nominal current A
6.5
9.5
11.4
15.9
7.3
9.2
Gas
R410a /
1200g
R410a/ 1700g
R410a /
1900g
R410a /
2500g
R410a/
2500g
R410a /
3200g
Heat exchanger
Titanium in
PVC-U Tank
Titanium in
PVC-U Tank
Titanium in
PVC-U Tank
Titanium in
PVC-U Tank
Titanium in
PVC-U Tank
Titanium in
PVC-U Tank
Compressor
Rotary
Rotary
Rotary
Scroll
Scroll
Scroll
Fan direction
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
Protection index
IP24
IP24
IP24
IP24
IP24
IP24
Noise level
dB(A) à
10m***
33.8 37.7 40.4 41.9 41.9 41.5
Sound Power
dB(A)
61.8 65.7 68.4 69.8 69.8 69.5
Outlet diameter
(mm)
50 50 50 50 50 50
Net weight / Gross
weight (kg)
55/ 63 70/ 80 72 / 82 105/ 117 105 / 117 123/ 138
*
COP : Coefficient of performance
**
Solar Cover when not bathing, use mid May-mid September, water temp 26 ° C, filtration mini 8h/day,
24h/24 to temperature setting, basin located in the department 13, 20m altitude (non-exhaustive criteria).
We recommend that you verify with a thermal study the choice of model.
*** :
Noise level is the acoustic value perceived by the human ear and measured by the SPL meter. It
depends on the installation environment and the distance at which the measure is made.