Explains BOD measurement via pressure difference in a closed system.
Lists uses for BOD determination and bio-technological applications.
Lists all items included with the OxiDirect measuring device.
Defines BOD as oxygen consumed by organic matter decomposition.
Details BOD measurement via pressure changes caused by oxygen consumption.
Outlines initial steps for sample preparation and measurement setup.
Describes the function of each control key on the OxiDirect unit.
Explains the different operational states of the OxiDirect unit.
Defines key terminology used throughout the manual for clarity.
Explains LED indicators and display codes with corresponding actions.
Continues explanation of display codes and required actions for operation.
Guides through the initial setup process, including battery installation.
Details how to turn the OxiDirect unit on and interpret initial display.
Explains the procedure for safely powering down the OxiDirect unit.
Instructions on how to access and view previously saved measurement data.
Describes how to view active measurement results in real-time.
Step-by-step guide for initiating a new BOD measurement process.
Introduces the menu for configuring system parameters.
Details how to set the device's internal clock and date accurately.
Explains the automatic start function and its impact on sample measurement.
Describes the automatic setting of measurement duration for samples.
Provides instructions for replacing the unit's batteries safely.
Explains how to transfer measurement data from the unit to a computer.
Contains important operational remarks and practical tips for the unit.
Relates BOD ranges to required sample volumes and ATH dosage.
Details steps for preparing water samples, including pH adjustment.
Continues sample preparation with nitrification inhibitor, KOH, and sealing.
Explains how to analyze BOD measurement data and identify potential issues.
Describes how to verify the functionality of the OxiDirect system.
Provides guidance on cleaning and maintaining the BOD measurement system components.
General instructions for using the inductive stirring system.
Specifies the intended application for the stirring system.
Explains warning and information symbols used in the manual.
Outlines essential safety precautions when using the stirring system.
Continues safety warnings regarding magnetism, voltage, and environment.
Details the components and operational characteristics of the stirring system.
Guides through the physical connection and setup of the stirring system.
Recommendations and specifications for magnetic stirring rods.
Instructions on how to operate the stirring process and stop it.
Procedures for cleaning and maintaining the stirring system components.
Identifies common problems and their solutions for the stirring system.
Addresses issues with uneven stirring rod rotation and potential causes.
Explains why stirring rods might swerve and how to fix it.
Lists the technical specifications for the OxiDirect BOD measurement system.
Details the technical specifications for the inductive stirring system.
Lists available accessories and replacement parts with their order codes.
| Interface | USB |
|---|---|
| Display | LCD |
| Resolution | 0.1 mg/L |
| Measuring Principle | Electrochemical |
| Number of Measuring Points | 6 |
| Temperature Range | 0 – 40 °C |
| Power Supply | 100 – 240 V / 50/60 Hz |
| Data Storage | Internal memory |