• Lamps will start to dim when the OFF TIME
equals the current time.
RAMP has a range of 1 to 240 (1 minute to 4
hours).
• The channel level setting allows the maximum
brightness of each channel to be set as a
percentage.
• The minimum level settings for each channel
are in operation when that channel is in the
OFF phase.
Please note: the minimum level cannot
exceed the maximum level. At ‘OFF TIME’
the units must dim and at ‘ON TIME’ the units
must brighten.
• A DEMO mode can be entered by holding the
MODE button during power up. A ‘D’ will be
displayed and the clock will run fast.
In DEMO mode, the lamps continuously
brighten and dim according to the user set
program over a 2 minute and 20 second
period. The ramp rate is fixed at approximately
10 seconds.
Please note: the clock displays the time of
day. However, 1 hour is reduced down to 6
seconds, making the full 24 hour cycle just 2
minutes and 20 seconds.
4
AquaRay MultiControl instructions v1-2010_Layout 1 11/06