Aquasafe WSL50 Pro - User Manual

Aquasafe WSL50 Pro
193 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AquaSafe
WSL50 Pro
Water Safety
Laboratory
Instruction
Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Aquasafe WSL50 Pro and is the answer not in the manual?

Summary

AquaSafe WSL50 Pro Water Safety Laboratory Instruction Manual

Section 1: Introduction to AquaSafe WSL50 Pro

Overview of the portable field laboratory for water quality testing.

Section 2: AquaSafe WSL50 Pro Kit Contents

Details of all components included in the AquaSafe WSL50 Pro kit.

Section 3: AquaSafe WSL50 Pro Operating Instructions

Guidance on operating the AquaSafe WSL50 Pro incubator.

3.1 Incubator Controls Overview

Explanation of the incubator's physical controls and switches.

3.2 Getting Started with the Incubator

Initial steps for setting up and starting the incubator.

3.3 Incubator Menu Options

Navigation and options within the incubator's menu system.

3.3.1 Menu Sequence for Left Chamber

Step-by-step menu flow for the left incubator chamber.

3.3.2 Menu Sequence for Right Chamber

Step-by-step menu flow for the right incubator chamber.

3.3.3 Understanding the Start Screen

Description of the initial display screen and its status indicators.

3.3.4 Using the 37°C Incubation Program

Instructions for using the pre-programmed 37°C incubation cycle.

3.3.5 Using the 44°C Incubation Program

Instructions for using the pre-programmed 44°C incubation cycle.

3.3.6 Setting User-Defined Incubation Programs

Procedure for setting custom temperature profiles for incubation.

3.3.7 Resetting the Incubator Timer

Steps to reset the incubator's timer and elapsed time data.

3.3.8 Adjusting Incubation Cycle Time

How to adjust the incubation cycle duration.

3.3.9 Setting User-Defined Temperatures

Guide to setting user-defined incubation temperatures.

3.3.10 Incubator Calibration Procedure

Instructions for calibrating the incubator's temperature.

4.0 Care and Maintenance for AquaSafe WSL50 Pro

Guidelines for maintaining and caring for the AquaSafe incubator.

4.1 General Maintenance Advice

General advice on the maintenance requirements of the incubator.

4.2 Incubator Cleaning Procedures

Detailed instructions on how to clean the incubator and its components.

4.3 Component Maintenance

Specific maintenance tasks for the incubator's parts.

5.0 AquaSafe WSL50 Pro Technical Specifications

Technical data for the AquaSafe WSL50 Pro.

5.1 Docking Station Specifications

Technical details regarding the docking station.

5.2 Incubator Specifications

Technical details regarding the incubator unit.

6.0 Guarantee and Assistance Information

Information on warranty coverage and how to get technical support.

AquaSafe Membrane Filtration Instruction Manual

SECTION 1: ASSEMBLY OF FILTRATION APPARATUS

Step-by-step guide to assembling the membrane filtration equipment.

SECTION 2: PREPARING BACTERIOLOGICAL MEDIA IN A LABORATORY FACILITY

Procedure for preparing microbiological media in a lab setting.

SECTION 3: PREPARING BACTERIOLOGICAL MEDIA IN THE FIELD

Method for preparing microbiological media in a field environment.

SECTION 4: WATER SAMPLING GUIDELINES

Guidelines and techniques for collecting water samples.

SECTION 5: USE OF BACTERIOLOGICAL MEDIA

Information on the proper use and storage of bacteriological media.

SECTION 6: CRITICAL ASEPTIC PROCEDURES

Critical aseptic techniques for microbiological analysis.

SECTION 7: PROCESSING SAMPLES FOR COLIFORM ANALYSIS

Steps for processing water samples for coliform analysis.

SECTION 8: COUNTING COLIFORMS AND RECORDING RESULTS

How to count coliform colonies and record the analysis results.

SECTION 9: OPTIMUM VOLUMES FOR MEMBRANE FILTRATION

Guidance on choosing appropriate sample volumes for accurate filtration.

HydroTest Photometer HT1000 Operation Manual

1.0 Introduction to the HT1000 Photometer

Overview of the HT1000 photometric analyser and its capabilities.

2.0 HT1000 Photometer Operation Guide

Comprehensive guide to the operation of the HT1000 photometer.

2.1.1 Meter Setup Procedures

Steps for initial setup and configuration of the photometer.

2.1.2 Important Information on Saving Data

Critical information regarding data saving during battery changes.

2.1.3 Photometer Battery Replacement

Procedure for safely replacing the photometer's batteries.

2.1.4 HT1000 Instrument Diagram

Labeled diagram illustrating the photometer's components.

2.2 Overview of Photometer Function Keys

Explanation of the functions of each key on the photometer.

2.2.2 Displaying Time and Date Settings

How to view the current date and time settings on the display.

2.2.3 Using the User Countdown Timer

Guide to setting and using the user-defined countdown timer.

2.2.4 Adjusting the Display Backlight

Instructions for adjusting the LCD display backlight.

2.3 Operation Modes on the HT1000

Overview of the different operational modes available on the photometer.

2.3.1 Configuring Automatic Switch Off

How to configure the automatic power-off feature.

2.3.2 Selecting a Measurement Method

Steps for selecting the appropriate measurement method.

2.3.3 Accessing Method Information [F1]

Accessing detailed information about selected measurement methods.

2.3.4 Chemical Species Information Retrieval

Viewing available chemical species and their ranges for a method.

2.3.5 Differentiating Measurement Results

How to differentiate results for methods like chlorine.

2.3.6 Performing Zero Point Calibration

Procedure for setting the instrument's zero point before measurement.

2.3.7 Conducting Measurement Tests

Steps involved in conducting a measurement test.

2.3.8 Changing Chemical Species for Tests

How to switch between different chemical species for a test.

2.3.9 Storing Measurement Results

Instructions for saving test results with optional codes.

2.3.10 Printing Results via PC-Link

Guidance on printing test results using the optional PC-Link.

2.3.11 Performing Additional Measurements

How to perform subsequent tests using the same method.

2.3.12 Selecting a New Measurement Method

Steps to choose and start a different measurement method.

2.3.13 Measuring Sample Absorbance

Procedure for measuring sample absorbance at specific wavelengths.

2.4.1 Instrument Basic Settings Part 1

Configuring initial instrument settings like language and key beep.

Setting Date and Time on the Photometer

How to set the instrument's internal clock and date settings.

Countdown Function Control

Managing the reaction time countdown feature.

Signal Beep Configuration

Adjusting audible signals for measurements and countdowns.

2.4.2 Printing Stored Results

Instructions for printing all stored measurement data.

Printing Results by Selected Time Period

How to print results within a specified date range.

Printing Results by Selected Code Number Range

Printing results based on a range of assigned code numbers.

Printing Results for a Selected Method

Printing data for a specific selected measurement method.

2.4.3 Recalling and Deleting Stored Results

Managing stored measurement data by recalling or deleting it.

Recall All Stored Results

Retrieving all saved measurement data from the instrument's memory.

Recall Results by Selected Time Period

Accessing stored results based on the date they were recorded.

Recall Results by Selected Code Number Range

Retrieving stored data using a range of code numbers.

Recall Results by Selected Method

Accessing stored results filtered by the measurement method used.

Delete All Stored Results

Process for clearing all stored measurement data from the instrument.

2.4.4 Photometer Calibration Procedures

Guides for calibrating various measurement methods.

Calcium Hardness Calibration (Method Blank)

Steps for calibrating calcium hardness using a method blank.

Reset Calcium Hardness Calibration to Factory

Restoring factory calibration settings for calcium hardness.

Fluoride Method 170 Calibration

Calibration procedure for the Fluoride Method 170.

User Calibration Functionality

How to perform custom calibration for specific methods.

Store User Calibration Data

Saving custom calibration factors for user-defined methods.

Delete User Calibration Settings

Removing custom calibration data from the instrument.

2.4.5 Lab Function - Profi-Mode

Using Profi-Mode for simplified routine analysis operations.

One Time Zero (OTZ) Functionality

Utilizing the One Time Zero feature for efficient calibration.

2.4.6 User Options Configuration

Customizing user options, including managing the method list.

User Method List Management

Creating and adapting a custom list of available measurement methods.

Switch All Methods On;Off

Enabling or disabling all measurement methods in the list.

User Concentration Methods Setup

Entering and storing custom concentration measurement methods.

Entering a User Concentration Method

Step-by-step guide to inputting a new user concentration method.

User Polynomials Setup and Storage

Entering and storing custom polynomial calibration curves.

Delete User Methods (Polynomials;Concentration)

Removing user-defined methods from the instrument.

Print User Method Data

Outputting data for user-defined polynomials and concentration methods.

Initialise User Method System

Resetting the user method system to default settings.

2.4.7 Special Functions Access

Accessing and using special functions of the photometer.

Langelier Saturation Index Calculation

Calculating the Langelier Saturation Index for water balance.

Langelier Index Calculation Steps

Detailed procedure for calculating the Langelier saturation index.

Temperature Unit Selection

Choosing between Celsius and Fahrenheit for temperature readings.

2.4.8 Instrument Basic Settings Part 2

Configuring display contrast and brightness settings.

Adjusting Display Contrast

Modifying the contrast level of the LCD display.

2.4.9 Instrument Special Functions and Service

Accessing system information and service functions.

Photometer Information Display

Viewing software version and memory status.

2.5 Data Transfer Options

Methods for transferring data to a PC or printer.

2.5.1 Printing Data Directly

Instructions for printing data using a connected printer.

2.5.2 Data Transfer to Personal Computer

Steps for transferring measurement data to a personal computer.

3.0 Enclosure and Technical Data

Information on the instrument's enclosure and detailed technical specifications.

3.1 Unpacking Instructions

Guidance on unpacking and inspecting the instrument.

3.2 Technical Data Summary

Summary of key technical specifications for the photometer.

3.3 Abbreviations and Definitions Glossary

Glossary of abbreviations and terms used in the manual.

3.4 Troubleshooting Guide

Solutions for common operating messages and error conditions.

3.4.1 Operating Messages and Errors

Explanations of display messages and corrective actions for errors.

APPLICATION NOTE T2 O-AN-P60 AMMONIA (P60) METHOD

APPLICATION NOTE T2 O-AN-P100 CHLORINE FREE & TOTAL (P100) METHOD

APPLICATION NOTE T2 O-AN-P260 NITRATE (P260) METHOD

APPLICATION NOTE T2 O-AN-P270 NITRITE (P270) METHOD

HydroCheck HC1000 Multi-Parameter Water Tester Manual

1.1 Introduction to the HydroCheck HC1000

Welcome and overview of the HydroCheck HC1000 meter.

1.2 Meter Unpacking Procedure

Steps for unpacking and checking the HydroCheck HC1000 meter.

1.3 List of Meter Accessories

Inventory of standard accessories included with the meter.

2.1 Display Information Overview

Explanation of the meter's LCD display elements and indicators.

2.2 Keypad Layout and Functions

Description of the meter's keypad and the function of each key.

2.3 Sensor Connector Identification

Details on the meter's connectors for various sensors.

2.4 Connecting Sensors to the Meter

Instructions for connecting pH, Conductivity, and DO sensors.

pH Electrode Connection Guide

Guide to connecting the pH electrode securely to the meter.

Conductivity Electrode Connection Procedure

Procedure for attaching the conductivity electrode to the meter.

Dissolved Oxygen Electrode Connection

Steps for connecting the DO probe to the meter.

2.5 Battery Insertion and Replacement

Instructions for installing and replacing the meter's batteries.

2.6 Refilling DO Probe Electrolyte Solution

Procedure for refilling the electrolyte solution in the DO probe.

Core Measurement Modes and Operations

Overview of basic operations and measurement modes.

3.1 Powering the Meter On;Off

How to turn the meter on, off, and manage auto-off functions.

3.2 pH Measurement Procedure

Steps for performing accurate pH measurements with the meter.

3.3 ORP Measurement Procedure

Guide to conducting ORP (Oxidation-Reduction Potential) measurements.

3.4 Conductivity, TDS, Resistivity Measurement

Instructions for measuring conductivity, TDS, and resistivity.

3.5 Salinity Measurement Procedure

How to measure salinity in practical and seawater modes.

3.6 Dissolved Oxygen Measurement

Steps for measuring dissolved oxygen levels in water samples.

3.6 Hold Functionality

Using the meter's data hold features to freeze readings.

3.7 Storing and Recalling Data from Memory

Managing stored measurement data, including input and recall.

4.1 Setup Menu Navigation

Accessing and navigating the meter's setup menu for configuration.

4.2 Adjusting Meter Settings

Procedures for adjusting various meter settings and parameters.

4.3 Exiting Setup Mode

How to exit the setup menu and return to measurement mode.

4.4 Setting Device Date and Time

Configuring the meter's internal clock and date settings.

4.5 Temperature Compensation Settings

Understanding and configuring temperature compensation for measurements.

Automatic Temperature Compensation (ATC)

Enabling and using the automatic temperature compensation feature.

Manual Temperature Compensation Entry

Manually inputting temperature values for compensation.

5.1 pH Calibration Procedures

Detailed guides for calibrating the pH sensor.

5.2 Single Point pH Calibration

Step-by-step guide for performing a single-point pH calibration.

5.3 Multi-Point pH Calibration

Instructions for conducting multi-point pH calibration.

5.4 pH Calibration with User-Defined Buffers

Calibrating the meter using custom pH buffer solutions.

5.5 pH Calibration Report Review

Checking the calibration status and diagnostic information for the pH electrode.

6.1 ORP Calibration Process

Steps for calibrating the ORP sensor.

6.2 ORP Calibration Report Review

Reviewing the calibration status and offset for the ORP electrode.

7.1 Conductivity Calibration Guide

Instructions for calibrating the conductivity sensor.

7.2 Single Point Conductivity Calibration

Performing a single-point calibration for conductivity measurements.

7.3 Multi-Point Conductivity Calibration

Conducting multi-point calibration for conductivity.

7.4 Manual Conductivity Calibration

Manually inputting cell constants for conductivity calibration.

7.5 Conductivity Calibration Report Review

Checking the calibration factor and date for the conductivity electrode.

8.1 DO Calibration in % Saturation Mode

Calibrating the DO sensor using percentage saturation.

8.2 100% Saturation Calibration

Performing a one-point calibration for DO at 100% saturation.

8.3 2 Point DO Saturation Calibration

Conducting a two-point calibration for DO saturation.

9.1 DO Calibration in mg;L or ppm Mode

Calibrating the DO sensor for concentration measurements.

9.2 2 Point DO Concentration Calibration

Performing a two-point calibration for DO concentration.

10.1 Temperature Calibration Procedure

Calibrating the meter's temperature sensor.

11.1 Electrode Care and Maintenance

Guidelines for cleaning, maintaining, and reactivating electrodes.

11.2 ORP Electrode Care and Maintenance

Instructions for cleaning and maintaining ORP electrodes.

11.3 Conductivity Electrode Care and Maintenance

Procedures for cleaning and maintaining conductivity electrodes.

11.4 DO Probe Care and Maintenance

Tips for keeping the DO probe membrane moist and maintaining it.

12.1 Troubleshooting Common Issues

Solutions for common problems and error messages displayed by the meter.

Appendix 1: Temperature Coefficient Calculation

Formula and method for calculating the temperature coefficient.

Appendix 2: TDS Conversion Factor Calculation

Formula for determining the TDS conversion factor.

Appendix 3: Pressure vs Altitude Table

Reference table correlating pressure with altitude.

14.1 Warranty Information and Support

Details on warranty terms and customer support contact information.

Aquasafe WSL50 Pro Specifications

General IconGeneral
BrandAquasafe
ModelWSL50 Pro
CategorySafety Equipment
LanguageEnglish

Related product manuals