AQUAFORCE
®
PUMP SPECS
Model Number 1000 1800 2700 3600 5200
Item Number #91011 #91112 #91012 #91113 #91013
Average Pond Size Recommendation
For Ponds up to 2,500
gallons
For Ponds up to 3,500
gallons
For Ponds up to 5,500
gallons
For Ponds up to 7,500
gallons
For Ponds up to 10,000
gallons
Maximum Flow Rate 1,070 GPH 2,149 GPH 2,695 GPH 3,868 GPH 5,284 GPH
Maximum Head Height 10 ft 16.5 ft 14 ft 18 ft 24 ft
Motor Type Asynchronous Asynchronous Asynchronous Asynchronous Asynchronous
Wattage 55 160 147 215 360
Amperage .51 1.33 1.25 1.8 3
Power Cord Length 25 ft 25 ft 25 ft 25 ft 25 ft
Pump Discharge Diameter
1.5” MPT
1.5” MPT 1.5” MPT 1.5” MPT 1.5” MPT
Multi-Hose Fitting Diameters 1”, 1.25”, 1.5”, 2”
1”, 1.25”, 1.5”, 2” 1”, 1.25”, 1.5”, 2” 1”, 1.25”, 1.5”, 2” 1”, 1.25”, 1.5”, 2”
Warranty 3 Year Limited 3 Year Limited 3 Year Limited 3 Year Limited 3 Year Limited
4
Installation
Always operate the pump fully submerged. Failure to do so
will overheat the pump and cause it to fail, thus voiding the
warranty. DO NOT OPERATE DRY.
Use only in fully assembled state, and be sure that both
the upper and lower cage screens are snapped together.
Failure to operate the pump without the fi lter cage closed
will allow large debris to enter the pump, causing the
pump to fail and voiding the warranty.
Do not wear loose clothing that may become entangled in
the impeller or other moving parts.
Keep clear of suction and discharge openings. DO NOT
insert fi ngers in pump with power connected.
Do not pump hazardous materials or liquids, such as oil,
saltwater or organic solvents.
Do not block or restrict discharge.
Products returned must be cleaned, sanitized, or
decontaminated, as necessary prior to shipment so as
to ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and
regulations shall apply.
IMPORTANT: Aquascape, Inc. is not responsible
for losses, injury, or death resulting from a failure
to observe these safety precautions, misuse or
abuse of pumps or equipment.
AQUAFORCE
®
SPECIFICATIONS
Input Voltage: 120V AC
Input Frequency: 60 Hz
Submersible pump
For outdoor or indoor use
Thermally protected
This pump has been evaluated for use with fresh water only
Input Amps & Wattage: See chart on next page
Typical Installation in an
ecosystem water garden
The AquaForce
®
Pump is designed to
be submerged directly into the pond.
To maximize pond circulation, locate
the AquaForce
®
pump as far away as
possible from the location of the water
entering back into the water feature.
It is recommended that the pump NOT
be positioned in the deepest area of
the pond. This will protect the fi sh by
preventing the pond from completely draining in the case
of leak in the plumbing or fi lter. Bricks or stones can be
used, if needed, to raise the pump up off the bottom of the
pond.