MOUNTING AND ATTACHING FLASHES
Depending on which strobe system you are using, you can mount the necessary shoes or brackets or Base Ball
onto the threaded holes on the top of the hand grips. Use of the Aquatica TLC Strobe Arm System is recommended.
There are also two 1/4”-20 threaded holes on the bottom of the housing that can be used for various mounting
applications. For example, Aquatica TLC makes a strobe arm mounting tray that will t on the bottom of the hous-
ing. A 1/4”-20 threaded hole on top of the housing will accept an Aquatica bracket or Base Ball that can hold a
small dive light or a strobe arm.
The AQUATICA Digital housing is tted with a standard Nikonos Type double bulkhead connector for strobes.
The secondary Bulkhead connector is disconnectable and a remote control cord (product #19300) attached to it,
allowing the housing to be used for remote photography
• When using the Standard Nikonos sync cord be sure to lubricate the O-ring on the sync cord’s connector with
a light coat of O-ring grease. Also put a light coat of O-ring grease on the threads of this connector.
TAKING A PICTURE
Following are the basic techniques. For more information and advanced photography please study the Nikon
D300 instruction manual.
1. Selelection of the exposure Mode (key # 4) is achieved through lifting the knob and positionning over the
button to engage the desired exposure mode, Exposure Mode options in sequence are: Programmed Auto (P),
Shutter Priority Auto (S), Aperture Priority Auto (A) or Manual Exposure (M) and are selected using the main sub
command dial control (key# 3).
2. Control of Auto Exposure compensation (key# 4) is achieved through lifting the knob and positionning over the
button to engage compensation function, select proper factor by rotating main command knob (key# 3) .
Note: When using a ash, it is reccomended that the camera be used only in Single Frame Motor Drive or there
is the possibillity that the camera will re before the ash can recycle.
3. Turn the Metering System Knob (key# 16) and select the metering system symbol you wish to use: 3D Matrix,
Center-Weighted or Spot, in the LCD panel.
4. Pull the Shutter Release Lever partially back. This will activate the camera’s meter and autofocus system.
5 If using manual focus use the Focus Knob (key # 6) on the housing or on the at port to focus.
6 If using the Manual, Aperture or Shutter priority mode adjust the Main Command Knob (key # 3) or
sub-command (key # 2) to set the shutter speed and/or aperture.
7. Pull the Shutter Release Lever (key # 1) the rest of the way until the camera res.