Model | FITOCLIMA 2500 HP |
---|---|
Humidity Range (min) | 10% RH |
Internal Volume | 2500 liters |
Shelving | Adjustable stainless steel shelves |
Temperature Uniformity | ±0.5°C |
Humidity Uniformity | ±2% RH |
Humidification System | Ultrasonic humidifier |
Dehumidification System | Refrigeration-based dehumidification |
Temperature Range (max) | +45°C |
Humidity Range (lights off) | 10% to 95% RH |
Humidity Range (lights on) | 40 to 90% RH |
Heating System | Electrical heaters |
Power Supply | 400V 3Ph 50Hz |
Lighting | adjustable intensity |
Data Logging | Built-in data logger, USB export |
Details the warranty coverage and conditions for the equipment.
Provides an overview of the manual's purpose and content.
Outlines essential safety precautions and warnings for operating the equipment.
Lists safety devices and conditions that trigger them to prevent damage.
Lists all items included with the climatic chamber upon delivery.
Provides a general overview of the FITOCLIMA 2500 HP climatic chamber.
Explains the intended use and application of the chamber for climatic tests.
Details the technical specifications and parameters of the climatic chamber.
Presents the interior and exterior dimensions of the equipment.
Describes the main system components of the climatic chamber.
Provides step-by-step instructions for installing the equipment.
Guides the user on how to connect and power on the equipment.
Explains the correct procedure for safely disconnecting the equipment.
Outlines the features and capabilities of the ClimaPlus500 Controller.
Describes the information displayed on the controller's main screen.
Explains how to access and navigate the controller's main menu.
Guides on how to configure set values for various parameters.
Details how to configure alarm settings for different parameters.
Explains the functionality for creating and managing programs.
Describes the structure and segments of a program.
Explains how to view and interpret the status of a running program.
Details how programs evolve through segments, including ramp functions.
Provides instructions on how to edit existing programs.
Explains how to start, pause, and stop program execution.
Lists various service functions available on the controller.
Shows how to view graphical and tabular status of chamber parameters.
Describes how to manage user access and chamber operational status.
Displays software and hardware information of the controller.
Explains how to access and view active and registered alarms.
Lists and explains various alarm messages and their causes.
Provides general information on the importance of maintenance.
Details routine maintenance tasks to be performed by the user.
Lists consumable items and their order references.
Provides instructions on how to clean the equipment.
Describes the professional maintenance services offered by ARALAB.
Explains how to obtain technical assistance and what information to provide.