Pele 345
MODEL: 345-DVTE31LN-1
GAS FIRED DIRECT VENT FIREPLACE
S/N 340000 AND UP
ARCHGARD FIREPLACE PRODUCTS
7116 Beatty Drive
Mission, BC V2V 6B4 Canada
200-3345-01
July 8, 2020
English and French Installation Manuals available through your
local dealer or visit our website at: www.archgard.com
Les manuels d'installation en anglais et en français son
disponibles chez votre détaillant local ou en visitant notre site
web: www.archgard.com
INSTALLER:
LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER:
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only) or
mobile home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gases, unless a certied kit is used.
INSTALLATION, OPERATION, AND
MAINTENANCE MANUAL
- Do not store or use gasoline or other ammable vapors or
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any
phone in your building
Leave the building immediately
Immediately call your gas supplier from a neighbor's
phone. Follow the gas suppliers instructions
If you can not reach your gas supplier, call the re
department
- Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in
serious injury, death, or property damage.
Gas Fireplace Energy E󰀩ciency Rating
67.98%
Based on CSA P.4.1-15

Table of Contents

Questions and Answers

  • D
    Doris JonesAug 15, 2025
    Why are the flames low on my Archgard Indoor Fireplace even when the remote is on high?
    • T
      Teresa OwensAug 15, 2025
      If the flames on your Archgard Indoor Fireplace's main burner are low even when the remote is set to high, wait two minutes. The Dynamic Start Advantage feature starts on low to build a draft, automatically increasing the flame size after two minutes. If the issue persists, have a service technician check for low inlet pressure or replace the valve motor.
  • W
    walkertimothyAug 18, 2025
    What to do if the pilot igniter is sparking but the pilot will not light on my Archgard Indoor Fireplace?
    • J
      John SingletonAug 18, 2025
      If the pilot igniter sparks but the pilot of your Archgard Indoor Fireplace won't light, verify the inlet gas pressure is within acceptable limits. Check all connections to the gas valve. Ensure fuel supply valves and the emergency shut-off valve are open. Check wiring connections from the control board to the valve. Make sure the pilot is set to the correct fuel and ensure the pilot head is clear of debris.
  • J
    John HughesAug 22, 2025
    What to do if the pilot lights but the main burner will not light and igniter continues to spark on my Archgard Indoor Fireplace?
    • B
      Bradley DiazAug 22, 2025
      If the pilot of your Archgard Indoor Fireplace lights, but the main burner won't light and the igniter continues to spark, check the pilot flame sensor rod and clean it with steel wool if dirty. Also, check the pilot hood and clean it with steel wool if it's dirty. Ensure the flame sensor wire is properly plugged into the control board and is not damaged. Adjust the pilot flame using the pilot adjustment screw if the flame is too long or too short, ensuring it fully engulfs the sensor rod and is stable. Check the supply pressure and ensure the ground wire from the pilot is connected to the fireplace ground location.
  • B
    Brady RodriguezAug 26, 2025
    Why does the pilot randomly go out on my Archgard Indoor Fireplace?
    • K
      Kaitlyn LoganAug 26, 2025
      If the pilot of your Archgard Indoor Fireplace was lit but randomly goes out, turn the fireplace on again. If it's in continuous pilot on-demand ignition mode, the system will turn off the pilot if the fireplace hasn't been used for seven days. You may also switch the fireplace to IPI mode. Have a service technician check for low inlet pressure.
  • B
    brendanbellAug 28, 2025
    What to do if the pilot lights, but the main burner will not light on my Archgard Indoor Fireplace?
    • K
      kramerpaulAug 28, 2025
      If the pilot of your Archgard Indoor Fireplace lights, but the main burner will not light, check and verify all wiring connections match the wiring diagram. Also, verify that the inlet and manifold pressure are within acceptable limits.
  • S
    sandra19Aug 31, 2025
    How to fix a pilot igniter that won't spark on my Archgard Indoor Fireplace?
    • K
      Katelyn FranklinAug 31, 2025
      If the pilot igniter of your Archgard Indoor Fireplace won't spark, ensure the ON/OFF override jumper is installed correctly. Also, ensure main power is ON and new batteries are installed in the remote control (3 x AAA) and backup battery pack on the control board (4 x AA). Make sure the remote is synced with the control board. Check the 3.15A fuse in the control board, replacing it if necessary. Ensure the remote is not in smart or thermostat mode. Finally, ensure the igniter wire is connected to the control board and is not damaged.
  • J
    Joe BrownSep 4, 2025
    Why do the lights not work on my Archgard Indoor Fireplace?
    • S
      Sandy SimsSep 4, 2025
      If the lights on your Archgard Indoor Fireplace do not work, ensure main power is ON and the fireplace is plugged in (it may be operating on back up batteries). Check the 3.15A fuse in the control board and replace it if necessary. Ensure the lights are connected to the control board. Replace the bulbs, as they may be burnt out.
  • R
    Ryan CarterSep 7, 2025
    Why do the fans not work on my Archgard Indoor Fireplace?
    • D
      Dr. Derrick WilliamsSep 7, 2025
      If the fans of your Archgard Indoor Fireplace do not work, ensure main power is ON and the fireplace is plugged in (it may be operating on backup batteries). Check the 3.15A fuse in the control board and replace it if necessary. Ensure the fans are connected to the control board.
  • A
    Angela AdkinsSep 12, 2025
    What does it mean if my Archgard Indoor Fireplace control module beeps twice and the red LED is on?
    • K
      Kimberly GonzalezSep 12, 2025
      If the control module of your Archgard Indoor Fireplace beeps twice when the On/Off button on the remote is pressed and the Red LED is On, replace the batteries in the remote battery pack.

Archgard Pele 345-DVTE31LN-1 Specifications

General IconGeneral
CategoryIndoor Fireplace
ModelPele 345-DVTE31LN-1
TypeDirect Vent
Fuel TypeNatural Gas or Propane
VentingDirect Vent
IgnitionElectronic Ignition
FinishBlack
BTU Input31, 000 BTU