EasyManua.ls Logo

ARCTIC HAYES STEM User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
WARNING:
• Handle with care, the tip of the probe is sharp and can cause injury.
To measure temperature in °C / °F follow the simple instructions.
• Switch on the thermometer by clicking the ON/OFF button once. (See fig 1)
The LCD will display the temperature. The thermometer will automatically
power off, after 15mins if no activity.
• Select the function you wish to measure in. °C (Celsius) or °F (Fahrenheit) by
pressing the °C/°F button once. (see Fig 1) The LCD shows the selected icon
in the bottom right hand corner.
• Remove the protective sheath from the stem probe.
• Insert the tip of the probe into the area or object to be tested (Only the first
20mm from the tip of the thermometer probe will gain an accurate reading/
temperature measurement).
• The Stem Thermometer has a DATA HOLD function, that can also show
Max/Min measurement achieved.
• To use the HOLD function simply press the HOLD button once (see Fig1) This
will show the icon HOLD on the right of the temperature reading.
• To show the Maximum (MAX) temperature recorded simply press the HOLD
button once more and the MAX icon will show on the top right.
• To show the Minimum (MIN) temperature recorded simply press the HOLD
button once again and the MIN icon will show below.
• To switch off the thermometer, press the ON/OFF button once. (See fig 1) Or
the thermometer will automatically power off, after 15mins if no activity.
• Always re-cover the stem probe with protective sheath after use to prolong
the life of the instrument.
• The thermometer will display “ ” icon when battery is running low. Replace
battery with CR1220 3V button cell.
• To replace the battery turn the battery compartment anti-clockwise (OPEN),
this will release the battery cover, insert battery with (+) of battery facing
outwards, Push battery cover back in place and turn clock-wise to lock.
Technical
• Temperature Range:
-50°C ~ 330°C / -58°F ~ 626°F
• Accuracy:
± 0.5% of reading ± 1.5°C (2.7°F)
• Resolution:
0.1°C/°F
• Out of Range Reset:
Should the thermometer go out of range:
Below -50°C the LCD panel will show “LO”
Above 330°C the LCD panel will show “HI”.
To reset the thermometer remove the battery completely, leave for approximately 10
seconds, then replace battery.
• IP Rating 54
• IPower:
1 x 3V “CR1220” Button Cell
Features
• 145mm x 4mm Stainless steel probe.
• 11mm LCD Display
• °C/°F Button.
• Max/Min/Hold Function.
Fig.1
°C / °F Selection
Hold / Max /
Min Button
ON/OFF
• Low Battery Indicator.
• Auto Power off (after 15mins) if no activity.
• Over range indicator.
• Combined Pocket clip/wall hanger.
Question and Answer IconNeed help?

Do you have a question about the ARCTIC HAYES STEM and is the answer not in the manual?

ARCTIC HAYES STEM Specifications

General IconGeneral
BrandARCTIC HAYES
ModelSTEM
CategoryThermometer
LanguageEnglish

Summary

Safety and Handling

Handling Precautions

Handle the thermometer with care, as the probe tip is sharp and can cause injury.

Operating Instructions

Powering On and Off

Switch the thermometer on or off by pressing the ON/OFF button once. It auto-powers off.

Temperature Unit Selection

Select between Celsius (°C) or Fahrenheit (°F) by pressing the °C/°F button.

Probe Insertion and Measurement

Remove the protective sheath and insert the probe tip into the area for accurate temperature measurement.

Data Hold, Max/Min Functionality

Use the HOLD button to display current, maximum, or minimum temperature readings.

Battery Replacement and Indicator

Replace the CR1220 battery when the low battery indicator is shown.

Technical Specifications

Temperature Range

The thermometer measures temperatures from -50°C to 330°C (-58°F to 626°F).

Accuracy and Resolution

Offers an accuracy of ±0.5% of reading ±1.5°C and a resolution of 0.1°C/°F.

Out of Range Indicators

Displays "LO" below -50°C and "HI" above 330°C. Reset by removing and replacing the battery.

IP Rating and Power Source

Features an IP54 rating and uses one 3V "CR1220" button cell battery.

Product Features

Probe and Display

Includes a 145mm x 4mm stainless steel probe and an 11mm LCD display.

Functionality and Indicators

Offers °C/°F selection, Max/Min/Hold, low battery, auto power off, and over-range indicators.

Design and Convenience

Features a combined pocket clip/wall hanger for portability and storage.