EasyManuals Logo

Argo AE735SCL User Manual

Argo AE735SCL
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Outdoor Unit: AE752SCL
Compressor
Type
Compressor model
Nominal input W
Compressor oil…Amount cc.
Coil resistance (Ambient temp. 20°C)
Overload relay
Safety devices Type
Operating Temp. Open °C
Close °C
Run capacitor µF
VAC
Fan & Fan Motor
Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Nominal output W
Coil resistance (Ambient temp. 25 °C )
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor µF
VAC
Heat Exch. Coil
Coil
Rows
Fin pitch mm
Face area
m
2
External Finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE
2
1,5
0,51
Acrylic baked-on enamel finish
80 ± 15
2
440
Aluminium plate fin / Copper tube
BRN-WHT: 98.5
WHT-PNK: 201.0
Thermal protector
130 ± 5
1…. Ø 400
KFG6-51SB5P…1
6…900
40
50
370
Propeller
Internal
Thermal protector
N/A
N/A
1700
FV50S …670
C-R: 1,780
C-S: 2,175
Rotary (Hermetic)
5KS205EAA21
15

Other manuals for Argo AE735SCL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo AE735SCL and is the answer not in the manual?

Argo AE735SCL Specifications

General IconGeneral
BrandArgo
ModelAE735SCL
CategoryAir Conditioner
LanguageEnglish

Related product manuals