1-2 Major Component Specifications
ASR409VHG
Controller PCB
Part No.
Controls
Fan & Fan Motor
Type
Q'ty ……. Dia. and lenght mm
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Running Amps A
Power input W
Coil resistance (Ambient temp. 20 °C )
BLU-BLK: 231,0
BLK-GRY: 50,2
GRY-RED: 27,8
RED-WHT: 119,5
WHT-BLU: 49,5
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor µF
VAC
Panel
Model
Flap motor
rating
rpm
nominal output W
coil resistance (25°C)
k
Dew proof heater
Electronic expansion valve
Coil
Coil resistance (20°C)
Valve body
Heat Exch. Coil
Coil
Rows
Fin pitch mm
face area m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
15,62 ± 15%
450
2,5
0,258
A
luminium plate fin / Copper tube
240 VAC
1,3
1
3
M2LB24ZA12
CR-X253GH
Centrifugal fan
R4E280-AK45-12 …1
4… 870
240 V, 26W
Microprocessor
1…. Ø 280
0,33
75
2
A
SGM0918
Internal thermal protector
160 ± 10K
130 ± 15K
DKV-MOZS438E0
IKV-24D18
YEL - GRY: 46ORG - GRY: 46
BLK - GRY: 46RED - GRY: 46