Ariston Chaffoteaux 3318905 - Advanced Settings and Diagnostics

Ariston Chaffoteaux 3318905
116 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
GB
0 OFF
1 ON
Turn the knob and set value 1 to activate
the anti-Legionnaire's disease function.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 1 Hydraulic scheme
Turn the knob to check or set the reference
hydraulic circuit diagram according to the
installation performed:
0 Not defi ned
1 Basic single-coil
2 Basic double-coil
3 Solar-electric
4 Heating integration
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 2 Electric resistance setting
Press the OK button.
Turn the knob and set value 1 if the user
desires that the heating integration - via
the heating element - occurs according to
a time schedule.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 3 Collector DeltaT pump ON
Press the OK button.
Turn the knob and set the temperature dif-
ference between the collector and storage
tank that determines the pump's activa-
tion.
NOTE: INCREASE THE VALUE IF THE
PUMP TURNS ON/OFF FREQUENTLY.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 4 Collector DeltaT pump OFF
Press the OK button.
Turn the knob and set the temperature dif-
ference between the collector and storage
tank that determines the pump's stoppage.
NOTE: DECREASE THE VALUE IF THE
PUMP TURNS ON/OFF FREQUENTLY.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 7 Recooling Function
Press the OK button.
Turn the knob and set value 1 to activate
the Recooling function.
NOTE: this function delays overheating of
the collector by cooling the indirect cylin-
der during the night.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 9 Collector Frost Protection T
Press the OK button.
Turn the knob and set value 0 for enhancing
the anti-freeze protection for the collector.
Set -20 if high percentages of glycol are
used.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 6 0 Flow rate solar circuit
The display will visualise the value of the
ow rate in the solar circuit.
(IMPORTANT: ADJUST THE FLOW RATE
ACCORDING TO THE NUMBER OF COL-
start-up