EasyManua.ls Logo

Ariston CLAS EVO SYSTEM 32 FF - Appliance Shut-Off Conditions; Safety Shut-off (Volatile Errors); Safety Shut-off: Insufficient Water Pressure; Safety Shut-off: Insufficient Circulation

Ariston CLAS EVO SYSTEM 32 FF
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
product description
Technical Data
GEN. NOTES
Model Name CLAS EVO 24 FF CLAS EVO 28 FF
CE certi cation (pin) 1312BR4793
Boiler type
C12-C32-C42-C52-C62-C82-B22-B22p-B32
ELECTRICAL PERFORMANCE
Max/min nominal heat input(Hi) kW 25,8 / 11,0 30,0 / 13,0
Max/min nominal heat input (Hs) kW 28,7 / 12,2 33,3 / 14,4
Max/min nominal heat input for hot water (Hi) kW 27 / 11,0 31,3 / 13,0
Max/min nominal heat input for hot water (Hs) kW 30 / 12,2 34,8 / 14,4
Heat output: max/min kW 24,2 / 9,8 28,1 / 11,6
D.H.W. Heat output: max/min kW 25,3 / 9,8 29,3 / 11,6
Combustion e ciency (at ue) Hi/Hs % 94,5 93,9
Gross e ciency of nominal heat input (60/80 °C) Hi/Hs % 93,8 / 84,5 93,6 / 84,3
Gross e ciency at 30 % at 47°C Hi/Hs % 93,6 / 84,3 93,2 / 83,9
Gross e ciency at minimum power Hi/Hs % 89,2 / 80,3 89,3 / 80,4
Number of e ciency stars (Directive 92/42/EEC) stars *** ***
Rating Sedbuk class D D
Ma. heat loss to the casing (ΔT = 50°C) % 0,7 0,3
Heat loss through the  ue when burner on
% 5,5 6,1
Heat loss through the  ue when burner o % 0,4 0,4
EMISSIONS
Residual discharge head Pa 100 104
Nox class class 3 3
Flue fumes temperature (G20) °C 105 114
CO2 content
2
(G20) % 6,5 6,4
CO content (0 %0
2
) ppm 50 92
O2 content2
(G20) % 8,8 8,9
Max capacity fumes (G20) kg/h 57,4 67,5
Excess air % 72 74
HEATING CIRCUIT
Load losses water side (max) ΔT=20°C (mbar) 200 200
Residual head for the system bar 0,25 0,25
Expansion vessel pre-charged pressure bar 1 1
Maximum central heating circuit pressure bar 3 3
Expansion vessel capacity l 8 8
Central heating temperature: max/min(high temperature range) °C 82 / 35 82 / 35
DOMESTIC HOT WATER CIRCUIT
Domestic hot water temperature max/min °C 60 / 36 60 / 36
Speci c ow rate of domestic hot water system (10 min. with ΔT=30°C))
instant boilers
l/min 12,5 14,1
D.H.W.  ow rate ΔT=25°C l/min 14,5 16,8
D.H.W.  ow rater ΔT=35°C l/min 10,4 12,0
Hot water comfort stars (EN13203) stars 3 3
D.H.W. minimum  ow rate l/min 1,7 1,7
Domestic hot water pressure max/min bar 7 7
ROOMELECTRICAL
DATA
Power supply voltage/frequency V/Hz 230/50 230/50
Power consumption W 112 129
Minimum operating room temperature °C +5 +5
Electric system grades of protection IP X5D X5D
Weight
kg 30 31

Table of Contents

Other manuals for Ariston CLAS EVO SYSTEM 32 FF

Related product manuals