EasyManua.ls Logo

Ariston Euro Combi A/27 MFFI - Removing the Main Heat Exchanger; Removing the Air Pressure Switch

Ariston Euro Combi A/27 MFFI
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.
Disconnect the electrical connections “K” and silicone pipes “L from their
connection points
(see fig. 1.20)
;
2.
Remove screws “J” on the top of the sealed chamber
(see fig. 1.21)
;
Use a No. 2 star tip screwdriver to remove the switch from the plate.
Fig. 1.21
Fig. 1.20
7
B029
1.
Drain the boiler of water;
2.
Release the two connection nuts “I” connecting the exchanger to the flow
and return pipes
(see fig. 1.18)
;
3.
Pull it straight out
(see fig. 1.19).
Removing the main heat
exchanger
Removing the air pressure switch
Fig. 1.18
I
Fig. 1.19
L
L
K
J
J