62 /
COMP
FM1
MAIN BOARD
RED
BLACK
U
V
W
Y/G
Y/G
L
L-PRO
T3
T4
H-PRO
Y/G
TP
V
U
C N 1 9
C N 5 1
C N 5 5
W
F AN1
~
BLACK
DRIVER BOARD
RED
7
7
YELLOW
BLUE
P-1
Applicable to the units
adopting DC motor only
Applicable to the units
adopting AC motor only
CAP1
C N 5 3
C N 4 1
C N 4 3
C N 3
C N 4
C N 1 0
C N 4 0
C N 2 2
C N 4 2
C N 4 4
C N 8
C N 9
C N 7
C N 2
C N 1
C N 5
C N 5 4
C N 5 2
3
C N 3 3
C N 6
5
BLACK
BLACK
SV
4- W AY1
OPTIONAL
NOTE:Four-way valve
is used in the
Cooling & Heating
unit only
BLUE
BLUE
HEA T_D
HEA T_Y
OPTIONAL
3
BLACK
RED
BLUE
BLUE
BLUE
YELLOW
RED
BLACK
RED
BLACK
EEV
C N 2 0
M
5 (6 )
A
C N 2 1
M
5 (6 )
B
C N 1 7
M
5 (6 )
C
C N 1 9
M
5 (6 )
E
C N 1 8
M
5 (6 )
D
C N 2 9
C N 2 8
C N 2
7
C N 2 6
T2B-A B C D E
CN13
INDOOR
PIPE OUT
TEMP A B C D E
L(C)
N(C)
S(C) L(D)
N(D)
S(D) L(E) N(E)
S(E)
NWORB
NWORB
EULB
EULB
KCALB
KCALB
CODE P ART NAME
COMPRESSOR
HEA T
4-W AY V AL VE
COMP
CAP1
EEV
ELECTRIC EXP ANSIVE
VAL VE
OUTDOOR AC F AN
F AN1
H-PRO
L-PRO
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
T3
T4
CONDENSER
TEMPERA TURE SENSOR
OUTDOOR AMBIENT
TEMPERA TURE SENSOR
CRANKCASE HEA TING
SV
L
PFC INDUCT OR
TH
HEA TSINK
TEMPERA TURE SENSOR
TP
EXHAUST
TEMPERA TURE SENSOR
FM1
OUTDOOR DC F AN
F AN MOT OR CAP ACIT OR
P ART NAMECODE
BLUE
BLUE
RDE
BLACK
BLACK
RDE
C N 3 0
POWER
SUPPLY
L
N
L(B)
N(B)
S(B)
L(A)
N(A)
S(A)
NWORB
EULB
KCALB
NWORB
EULB
KCALB
NWORB
EULB
KCALB
C N 1 6
Y/G
TO B
Y/G
TO C
Y/G
TO E
Y/G
TO A
Y/G
TO D
DR BOARD
CN1
4
RJ45
FOR USER
TO CONNECT
OPTIONAL
CN5
OPTIONAL
RED
BLUE
CN2
OLP TEMP . SENSOR
C N 1 4
OPTIONAL:
TOP TEMPERATURE
PROTECTION OF
COMPRESSOR
Notes:
This symbol indicates the element
is optional,the actual shape
shall be prevail.
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
PENTA 121 XD0C-O
COMP
FM1
MAIN BOARD
U
V
W
Y/G
Y/G
L
L-PRO
T3
T4
H-PRO
Y/G
TP
V
U
C N 1 9
C N 5 1
C N 5 5
W
F AN1
~
BLACK
DRIVER BOARD
RED
7
7
YELLOW
BLUE
P-1
Applicable to the units
adopting DC motor only
Applicable to the units
adopting AC motor only
CAP1
C N 5 3
C N 4 1
C N 4 3
C N 3
C N 4
C N 1 0
C N 4 0
C N 2 2
C N 4 2
C N 4 4
C N 8
C N 9
C N 7
C N 2
C N 1
C N 5
C N 5 4
C N 5 2
3
C N 3 3
C N 6
5
BLACK
BLACK
SV
4- W AY1
OPTIONAL
NOTE:Four-way valve
is used in the
Cooling & Heating
unit only
BLUE
BLUE
HEA T_D
HEA T_Y
OPTIONAL
3
BLACK
RED
BLUE
BLUE
BLUE
YELLOW
RED
BLACK
RED
BLACK
EEV
C N 2 0
M
5 (6 )
A
C N 2 1
M
5 (6 )
B
C N 1 7
M
5 (6 )
C
C N 1 9
M
5 (6 )
E
C N 1 8
M
5 (6 )
D
C N 2 9
C N 2 8
C N 2 7
T2B-A B C D E
CN13
INDOOR
PIPE OUT
TEMP A B C D E
CODE P ART NAME
COMPRESSOR
HEA T
4-W AY V AL VE
COMP
CAP1
EEV
ELECTRIC EXP ANSIVE
VAL VE
OUTDOOR AC F AN
F AN1
H-PRO
L-PRO
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
T3
T4
CONDENSER
TEMPERA TURE SENSOR
OUTDOOR AMBIENT
TEMPERA TURE SENSOR
CRANKCASE HEA TING
SV
L
PFC INDUCT OR
TH
HEA TSINK
TEMPERA TURE SENSOR
TP
EXHAUST
TEMPERA TURE SENSOR
FM1
OUTDOOR DC F AN
F AN MOT OR CAP ACIT OR
P ART NAMECODE
BLUE
BLUE
RDE
BLACK
BLACK
RDE
C N 3 0
POWER
SUPPLY
NWORB
EULB
KCALB
C N 1 6
Y/G
TO B
Y/G
TO C
Y/G
TO A
TO D
DR BOARD
CN1
4
RJ45
FOR USER
TO CONNECT
OPTIONAL
CN5
OPTIONAL
RED
BLACK
CN2
OLP TEMP . SENSOR
C N 1 4
OPTIONAL:
TOP TEMPERATURE
PROTECTION OF
COMPRESSOR
L(B) N(B) S(B) L(C) N(C) S(C) L(D) N(D) S(D)
L
N
L(A) N(A) S(A)
NWORB
NWORB
EULB
EULB
KCALB
KCALB
NWORB
EULB
KCALB
Y/GY/G
Y/G
3
3
33
3
KCALB KCALB
DER
QUAD 110 XD0C-O
NOTA: COLLEGAMENTI A CURA DELL’INSTALLATORE / NOTE: WIRING TO BE DONE BY THE INSTALLER
ATTENZIONE! La posizione dei terminali potrebbe essere dierente
WARNING! The actual shape of the components may be dierent

Table of Contents

Related product manuals