Heat pump water heater – GENERAL INFORMATION
32
PERFORMANCES
measurement
80 L 100 L 110 L
COP (
A
)
2,9 2,9 2,9
Heating time with heat pump (
A
)
h:min 2:45 3:26 3:42
Heating energy consumption (
A
)
kWh 1,20 1,53 1,64
of hot water in
a single intake
V
40
(
B
)
Delivered at 55 °C
l 95 130 144
Delivered at 62 °C
l 113 152 169
Max. water temperature with heat
pump
°C
62 (55 factory default
setting)
62 (55 factory default
setting)
62 (55 factory default
setting)
Max. water temperature with
heating element
°C
75 (65 factory default
setting)
75 (65 factory default
setting)
75 (65 factory default
setting)
QPr (over 24 h) KWh 0,46 0,50 0,50
Power source
Voltage / max. power consumption
(
A
)
V / W 220-240 single-phase / 1950
Frequency Hz 50
Max. current consumption A 8,5
(
A
) values obtained with air temperature of 7 °C, 87% relative humidity; input water temperature 15 °C, setting
temperature 55 °C, in compliance with EN255-3 norm. Refrigerant connection length 6 m.
(
B
) Performance measured for input water temperature 15 °C.
(
C
) outside of the heat pump’s interval of operation, heating of the water is ensured by the heating element..
Average value obtained on a significant number of products.