EasyManua.ls Logo

Armada Technologies Pro48 - Specifications; Electrical Specifications; Solenoid Activation Range; Physical Dimensions and Weight

Armada Technologies Pro48
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
SPECIFICATIONS
Electrical Connections
Minimum Voltage for Clock LED is 18 Vac.
Minimum Battery while Testing is 15 Vdc.
Maximum Input Voltage between Test Leads is 28 Vac.
Solenoid Circuit Recharge Time is 0.5 sec
Peak output voltage is 36 Vdc.
Solenoid activation Range
NOTE: Depends on battery condition.
12 AWG Loop …… 3000-13000 feet
14 AWG Loop …… 2000-8500 feet
18 AWG Loop …… 500-3000 feet
Physical Size
Pro48 Multi-Function Irrigation Tester
Length ………….. 160 mm (6.0“)
Width ……………. 80 mm (3.0”)
Depth …………35 mm (1.5)
Weight…………... 0.27 kg (9.6 oz.)
Pro210F Tone Probe
Length …………….. 240 mm (9.5“)
Width ……………… 50 mm (1.9”)
Depth ……………... 50 mm (1.9”)
Weight ……………. 0.12 kg (4.5 oz.)
Temperature
Operation and storage
0° C to 50° C (32° F to 122° F)