7
SPECIFICATIONS
Electrical Connections
• Minimum Voltage for Clock LED is 18 Vac.
• Minimum Battery while Testing is 15 Vdc.
• Maximum Input Voltage between Test Leads is 28 Vac.
Solenoid Circuit Recharge Time is 0.5 sec
• Peak output voltage is 36 Vdc.
Solenoid activation Range
NOTE: Depends on battery condition.
• 12 AWG Loop …… 3000-13000 feet
• 14 AWG Loop …… 2000-8500 feet
• 18 AWG Loop …… 500-3000 feet
Physical Size
Pro48 Multi-Function Irrigation Tester
Length ………….. 160 mm (6.0“)
Width ……………. 80 mm (3.0”)
Depth …………… 35 mm (1.5”)
Weight…………... 0.27 kg (9.6 oz.)
Pro210F Tone Probe
Length …………….. 240 mm (9.5“)
Width ……………… 50 mm (1.9”)
Depth ……………... 50 mm (1.9”)
Weight ……………. 0.12 kg (4.5 oz.)
Temperature
Operation and storage
0° C to 50° C (32° F to 122° F)