4
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-DO NOT EXPOSE TO RAIN. STORE INDOORS.
WARNING:
FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL. DO NOT RUN
UNATTENDED. DO NOT PICK UP HOT ASHES OR COALS, OR TOXIC, FLAMMABLE, OR OTHERWISE
HAZARDOUS MATERIALS. DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.
CAUTION:
• Do not vacuum drywall dust or replace soot or ash with standard Wet/Dry lter. This type of dust is very ne which may
not be captured by the lter and cause damage to motor. When vacuuming ne dust, use a ne dust lter.
WARNING:
SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM WITH A DOUBLE-INSULATED WET/
DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING. NO GROUNDING
MEANS IS PROVIDED ON A DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING
BE ADDED. SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND
KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL.
REPLACEMENT PARTS FOR A DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS
THEY REPLACE. YOUR DOUBLE-INSULATED WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE
INSULATED’ AND THE SYMBOL (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE
APPLIANCE.
• DO NOT use without lters in place.
CAUTION:
TO REDUCE THE RISK OF INJURY FROM MOVING PARTS, UNPLUG BEFORE SERVICING.
EXTENSION CORDS
When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required A.W.G. wire
size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs
or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.
DOUBLE INSULATION INSTRUCTIONS
This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only identical
replacement parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before servicing.
Use this Wet/Dry Vac as described in this manual. Observe the following warnings that appear on the motor housing of
your Wet/Dry Vac.
DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE ONLY IDENTICAL
REPLACEMENT PARTS.
Length of Extension Cord
120V 25ft (7.62m) 50ft (15.24m) 100ft (30.48m) 150ft (45.72m)
Ampere rating
A.W.G. Wire Size
More than Not more than
0 6 18 16 16 14
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not recommended