Specifications
Input power requirements: 16.5 - 18VAC, 20 VA
Standby battery: 12-volt battery, 7AH (NP7-12) rechargeable
gel-type, not supplied
Temperature operating range: 32
o
to 120
o
F
Auxiliary power output: 12.5VDC regulated, 500mA
Bell output: Burglary/fire output, 12.5 VDC, 500mA
Loop Response: 10 - 300mSec. (1 second when dialing)
Maximum loop resistance: Not to exceed 300 Ohms on any
loop (does not include EOL resistor)
Transient and lightning protection: Lightning and surge
protection on all input, power and telephone lines
Dimensions: 13"H x 9"W x 3"D
Shipping weight: 10 lbs.
FCC registration number: 4T2USA-24862-AL-E
Ringer Equivalence: 0.2B
Compliance: UL Listed
Order Information
SP850: SP850 control packaged with EOL resistors, spare fuses
and metal enclosure.
KP600F Keypad: Digital arming station that allows full system
status. 7 separate LEDs provide system status. Backlit keys.
Comes with back box for surface mounting.
Dimensions: 4.500” X 4.510”X 1.110”
KP600L Keypad: Alphanumeric LCD arming station that allows
full system status from one or more convenient locations. 1 line
of 16 character display zone status and alarm memory for each
zone; Ready and arm status LEDs included.
Dimensions: 6.570” X 4.670”X 1.100”
DOB: Data Output Board. One DOB may be connected to a
SP850 for special outputs.
Keypad Controlled User Functions
Arming/Disarming
Bypassing zones or zone groups
System test
Four emergency 24-hour programmable functions
Duress
Smoke detector reset
Chime feature
Set time/date
Fault Analysis: AC Loss, Low Battery, Zone Trouble, Failure
to Communicate
Digital Communicator Features
Split reporting up to three 20-digit telephone number with
three separate account numbers
Three or four digit account numbers
Opening/closing reports up to 8 users
Programmable reporting attempts
Failure to communicate annunciation at keypad
Zone bypass, Test time reporting
Silent Knight 4+2; standard pulse reporting formats
ScanPro FSK formats, 300-baud software available
Alarm, Trouble, Restoral reports by zone
Remotely shut down nonpaying accounts
Remote high speed up/downloading from IBM-compatible
Programmable Software Features
"Follower" zones
2 Assignable outputs
Opening/closing reports
Automatic test report to any combination of 3 phone numbers
Dynamic low battery/restoral reporting; programmable
reporting delays
False alarm shutdown
Software delete of EOL resistors
Call back security