Arrowhead Elite S Specifications

General IconGeneral
BrandArrowhead
ModelElite S
CategorySecurity System
LanguageEnglish

Summary

Zone Trouble Shooting (single EOL)

Normally Closed (N/C) PIR Diagram

Diagram showing N/C PIR connection with 2k2 EOL resistor.

Normally Open (N/O) Smoke Detector Diagram

Diagram showing N/O Smoke Detector connection with 2k2 EOL resistor.

Zone Doubling Type 15 Configuration

Type 15: PIR-A (N/C) and PIR-B (N/C) Wiring

Wiring for Type 15 zone doubling with two N/C PIR detectors.

Type 15: PIR (N/C) and Smoke (N/O) Wiring

Wiring for Type 15 zone doubling with N/C PIR and N/O Smoke detector.

Type 15: Smoke (N/O) and PIR (N/C) Wiring

Wiring for Type 15 zone doubling with N/O Smoke and N/C PIR detectors.

Type 15: Smoke-A (N/O) and Smoke-B (N/O) Wiring

Wiring for Type 15 zone doubling with two N/O Smoke detectors.

Zone Doubling Type 14 Configuration

Type 14: PIR-A (N/C) and PIR-B (N/C) Wiring

Wiring for Type 14 zone doubling with two N/C PIR detectors and tampers.

Type 14: PIR (N/C) and Smoke (N/O) Wiring

Wiring for Type 14 zone doubling with N/C PIR and N/O Smoke detector with tampers.

Type 14: Smoke (N/O) and PIR (N/C) Wiring

Wiring for Type 14 zone doubling with N/O Smoke and N/C PIR detectors with tampers.

Zone Wiring Examples Type 14

Type 14 Zone Wiring: Star Configuration

Example of Type 14 zone wiring where cables return to the control panel.

Type 14 Zone Wiring: Series Configuration

Example of Type 14 zone wiring with daisy-chained detectors.

Reed Switch Wiring Configurations

Single EOL (Type 3) Reed Switch Wiring

Wiring diagram for a single EOL Type 3 standard zone with a reed switch.

Double EOL (Type 12) Reed Switch Wiring

Wiring diagram for a double EOL Type 12 zone with tamper and reed switch.

Dual EOL (Type 15) Reed Switch Wiring

Wiring diagram for a dual EOL Type 15 zone with two reed switches.

Double EOL (Type 14) Reed Switch Wiring

Wiring diagram for a double EOL Type 14 zone with two reed switches and tamper.

Type 14 Reed and PIR Wiring

Wiring diagram for Type 14 zone with both Reed and PIR detectors.

Smoke Detector Zone Wiring (Type 3)

Type 3: Single Smoke Detector Wiring

Wiring diagram for a single smoke detector connected to Zone 4 (Type 3).

Type 3: Multiple Smoke Detector Wiring

Wiring diagram for multiple smoke detectors daisy-chained to Zone 4 (Type 3).

Keypad Bus Troubleshooting Checks

Keypad Power Supply Check

Procedure to check power supply voltage at the keypad connection.

Keypad Clock Signal Check

Procedure to check clock signal voltage at the keypad connection.

Keypad Data Signal Check

Procedure to check data signal voltage at the keypad connection.

Wireless Receiver Troubleshooting (RX-16MF349)

Wireless Device Learning Issues

Troubleshooting steps for devices failing to learn into the wireless receiver.

Wireless Receiver Poor Range Issues

Troubleshooting steps to improve wireless signal range and reception.