EasyManua.ls Logo

ARTEX ME406HM - User Manual

ARTEX ME406HM
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1 of 72
Mar 19/2015
570-1600 Rev. V
Initial Issue JUN 30/2005
ARTEX PRODUCTS / ACR ELECTRONICS, INC.
5757 Ravenswood Rd, Ft. Lauderdale, FL 33312
Cage Code: 18560
25-62-30
ME406 Series
Emergency Locator Transmitter
Description, Operation, Installation and Maintenance Manual
This manual includes data for the equipment that follows:
Component Part No. Model No.
Emergency Locator Transmitter 453-6603 ME406
Emergency Locator Transmitter 453-6604 ME406HM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ARTEX ME406HM and is the answer not in the manual?

Summary

INTRODUCTION

Manual Usage

Guidance on using the ME406 Series ELT, including general info, application, and model descriptions.

DESCRIPTION AND OPERATION

Description

Covers the functional overview and components of the ME406 Series ELT.

Operation

Explains how to operate the ELT, including normal function, activation, and reset procedures.

Specifications

Details the environmental, physical, and electrical specifications of the ME406 Series ELT.

TEST AND FAULT ISOLATION

Inspection and Test Procedures

Provides step-by-step procedures for inspecting and testing the ELT.

Fault Isolation

Offers guidance for troubleshooting ELT malfunctions and interpreting error codes.

REMOVAL

ELT Removal

Details the procedure for removing the ELT from its mounting tray and aircraft.

INSTALLATION

ELT Installation

Outlines the sequence for installing the ELT into its mounting tray and performing initial tests.

ILLUSTRATED PARTS LIST

Detailed Parts List

Lists all spare parts and their associated information, cross-referenced with figures for easy identification.

ARTEX ME406HM Specifications

General IconGeneral
TypeEmergency Locator Transmitter (ELT)
Frequency406 MHz
Battery Life5 years
Waterproof RatingIP67
Power Output5W (406 MHz), 50mW (121.5 MHz)
Activation MethodManual or automatic (G-switch)
Operating Temperature-20°C to +55°C