EasyManua.ls Logo

arya PONZA Series - User Manual

arya PONZA Series
149 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MANUALE UTENTE
USER MANUAL | MANUAL DE USUARIO | BENUTZERHANDBUCH
IMPORTANTE:
PONZA INVERTER SERIES
MONOSPLIT PARETE
w elLnes s a i r
Leggere attentamente questo manuale prima dell'in -
stallazione o prima di azionare la macchina. Si prega di
conservare il manuale per cunsultazioni future.
Si prega di controllare i modelli applicabili, tecnici dati,
F-GAS (se presente) e informazioni sul produttore dal
"Manuale di istruzioni - Scheda prodotto" nell'imballo
dell'unità esterna.
(Solo prodotti dell'Unione Europea)
IT | EN | ES | DE
Question and Answer IconNeed help?

Do you have a question about the arya PONZA Series and is the answer not in the manual?

Overview

This document describes the ARYA PONZA INVERTER SERIES MONOSPLIT PARETE air conditioner, providing details on its functions, technical specifications, usage, and maintenance.

Function Description

The ARYA PONZA INVERTER SERIES MONOSPLIT PARETE is an air conditioning unit designed for domestic environments, offering cooling, heating, dry, and fan-only modes. It incorporates an inverter system for efficient operation across a range of temperatures.

  • Cooling Mode (FRESH): Cools the ambient air and simultaneously reduces humidity.
  • Heating Mode (HEAT): Heats the room. In heating mode, the appliance may automatically activate a defrost cycle to clear frost from the condenser and restore heat exchange efficiency. This process typically lasts 2-10 minutes, during which indoor and outdoor fans stop. Heating resumes automatically after defrosting. For low-temperature heating models, a forced defrost can be initiated by pressing the ECO button 10 times within 8 seconds.
  • Dry Mode (DRY): Reduces air humidity to enhance comfort. This mode activates an automatic preset function.
  • Fan Only Mode (FAN): Operates the fan without cooling or heating. Fan speed can be adjusted through AUTO, MUTE, LOW, LOW-MID, MID, MID-HIGH, HIGH, and TURBO settings.
  • Automatic Mode (AUTO): Automatically sets the operating mode based on ambient temperature.
  • ECO Function (ECHO): Optimizes operation for energy saving. This function is available in both cooling and heating modes.
  • MUTE Function (MUTE): Activates a silent operation mode, running the indoor unit fan at the lowest speed. This function cannot be activated in dry mode.
  • SLEEP Function (TO SLEEP): Activates an automatic operating program for sleep, with the display showing the SLEEP icon. After 10 hours, the air conditioner reverts to the previous setting.
  • DISPLAY Function (SCREEN): Turns the LED display on or off.
  • SWING Function: Controls the movement of louvers. It can activate horizontal flaps (up-down oscillation) and vertical flaps (left-right oscillation). Long pressing the button for more than 3 seconds allows selecting multiple airflow directions.
  • TURBO Function (TURBO): Activates a rapid cooling or heating mode, running the fan at maximum speed for a strong airflow.
  • I FEEL Function (I FEEL): Allows the remote control to measure the temperature at its current location and send this signal to the air conditioner to optimize temperature and comfort. This function automatically deactivates after 2 hours.
  • GEN Function (GEN): Activates a general mode with selectable types (L3, L2, L1, OF).
  • SELF-CLEANING Function (CLEAN): Helps remove accumulated dirt and bacteria from the internal evaporator. This function runs for approximately 30 minutes and then returns to the preset mode. It can be canceled during the process.
  • HEALTH Function (HEALTH): Activates ionizer, plasma, bipolar ionizer, or UVC lights (depending on the model) for air purification.
  • MOLD PROOF Function (MOLD PROOF): In cooling/drying mode, when the air conditioner is turned off, the indoor unit continues to run for about 15 minutes to dry the unit and prevent mold growth.
  • 8°C Heating Function (8°C.heating): Automatically starts heating when the room temperature is below 8°C (46°F) and returns to standby if the temperature reaches 9°C (48°F). This function automatically cancels if the ambient temperature exceeds 18°C (64°F).
  • CHILD-LOCK Function (MODE + TIMER): Locks the remote control to prevent accidental changes.
  • GENTLE WIND Function (FAN + MUTE): Automatically closes vertical flaps to provide a gentle airflow.

Important Technical Specifications

  • Refrigerant Type: R32, a flammable refrigerant.
  • Minimum Room Area: The appliance must be installed, operated, and stored in a room with a floor area larger than 4m². Specific minimum room areas are provided based on the refrigerant charge amount (M) and installation height (h0). For R32, the lower flammable limit (LFL) is 0.038 kg/m³.
  • Piping Length and Additional Refrigerant (9K-12K / 18K-24K models):
    • Standard charge pipe length: 5m
    • Maximum distance between indoor and outdoor unit: 25m
    • Additional refrigerant charge: 15g/m² (9K-12K) / 25g/m² (18K-24K)
    • Maximum difference in level between indoor and outdoor unit: 10m
  • Torque Parameters for Pipe Sizes:
    • 1/4" (Ø 6.35): 18-20 Nm (24.4-27.1 lbf-ft, 2.4-2.7 kgf-m)
    • 3/8" (Ø 9.52): 30-35 Nm (40.6-47.4 lbf-ft, 4.1-4.8 kgf-m)
    • 1/2" (Ø 12): 45-50 Nm (61.0-67.7 lbf-ft, 6.2-6.9 kgf-m)
    • 5/8" (Ø 15.88): 60-65 Nm (81.3-88.1 lbf-ft, 8.2-8.9 kgf-m)
  • Dedicated Distribution Device and Wire for Air Conditioner:
    • Power supply cable (N, L, Ground): 1.5mm² (for 9K-18K models), 2.5mm² (for 24K models).
    • Connection cable (1, N, 2, L, Ground): 0.75mm² (for 9K-24K models), with some models using 1.0mm² or 1.5mm² for specific connections.
  • Minimum Indoor Clearances:
    • Above unit: ≥20 cm / 8 inches
    • Sides: ≥13 cm / 5 inches
    • Below unit: ≥250 cm / 8 feet (from floor)
  • Operating Temperature Conditions (Inverter Air Conditioner):
    • Room temperature: 0°C ~ 30°C (heating), 17°C ~ 32°C (cooling), 17°C ~ 32°C (dry).
    • Outdoor temperature: -20°C ~ 30°C (heating), -15°C ~ 53°C (cooling/dry).

Usage Features

  • Remote Control: The unit is operated via a remote control with various buttons for mode selection, temperature adjustment, fan speed, timer settings, and special functions. The remote control uses 2 AAA (1.5V) LR03 batteries.
  • Emergency Button: In case of remote control failure, an emergency button located on the electronic control box (behind the indoor unit panel) can be used to switch between cooling, heating, and off modes.
  • Temperature Display: The remote control can display temperature in either Celsius (°C) or Fahrenheit (°F).
  • Safety Features: The appliance includes protection devices that may stop operation if temperatures exceed specified ranges. It also has a child lock function on the remote control.
  • Airflow Direction: Louvers and deflectors can be adjusted to direct airflow. In heating mode, flaps should be directed downwards, and in cooling mode, upwards.

Maintenance Features

  • General Cleaning:
    • Always turn off the machine and disconnect power for at least 5 minutes before cleaning.
    • Never flush the air conditioner with water.
    • Use a soft, dry cloth or a damp cloth with neutral detergent for cleaning. Avoid volatile liquids like thinner or gasoline.
  • Filter Cleaning:
    • Regularly clean the air filter to prevent dust accumulation and maintain efficiency.
    • To remove the filter, grasp its raised handle and pull it out, separating the top edge from the unit. Lift the filter upwards.
    • To install, insert the lower end of the filter screen into the corresponding position, then press the upper end into place.
    • Avoid touching the indoor unit's fins after removing the filter to prevent scratches.
  • Inner Air Duct Cleaning:
    • Loosen the knob on the louver, bend it outwards to remove.
    • Grasp both sides of the bottom plate and push downwards to remove it.
    • Loosen the buckle of the deflector assembly with your thumb to remove.
    • Wipe the air duct and fan assembly with a clean, wrung wet rag.
    • Clean removed parts with soapy water and air dry. Reassemble in reverse order after cleaning.
  • Long-Term Shutdown:
    • Remove batteries from the remote control.
    • Disconnect the air conditioner from the power supply.
  • Restart After Long-Term Shutdown:
    • Clean the unit and filter screen.
    • Check for obstacles at the air inlet and outlet of both indoor and outdoor units.
    • Verify that the drain pipe is unobstructed.
    • Install remote control batteries and check power.
  • Refrigerant System Maintenance (R32 specific):
    • Installation and maintenance must be performed by specialized technical personnel.
    • Ensure proper ventilation and absence of ignition sources due to the flammable nature of R32 refrigerant.
    • Leak detection methods (soapy water or professional detectors) must be used after installation and during maintenance.
    • Proper procedures for refrigerant removal and evacuation must be followed, including purging with oxygen-free nitrogen (OFN).
    • Electrical components must be checked for correct specifications and safety.
    • Repairs to sealed components and intrinsically safe components require specific procedures and qualified personnel.
    • The appliance must be labeled indicating its refrigerant content and decommissioning status.
  • Troubleshooting: The manual provides a comprehensive list of malfunctions, possible causes (e.g., power failure, damaged motor, faulty circuit breaker, dirty filter, refrigerant leakage), and corresponding error codes displayed on the indoor unit (E1-EH).
  • Disposal Guidelines (European): The appliance contains refrigerant and potentially hazardous materials. It must not be disposed of as unsorted municipal waste. Options include municipal electronic waste facilities, retailer take-back programs, manufacturer take-back, or certified scrap metal dealers. Disposal in natural environments is prohibited.

arya PONZA Series Specifications

General IconGeneral
Brandarya
ModelPONZA Series
CategoryAir Conditioner
LanguageEnglish