Do you have a question about the ASCENSIA CONTOUR NEXT ONE and is the answer not in the manual?
For measurement of blood glucose in patients with diabetes.
Crucial warnings on critical readings, serious illness, and consulting healthcare professionals.
Handling of meter, lancets, and test strips requires caution due to infection risk.
System tested up to 6301m; xylose absorption testing may interfere with results.
Read guides, check parts, use correct materials, store strips properly to avoid damage.
Identifies meter buttons, test strip port, and sample tip for basic operation.
Explains meter screen layout and meaning of various symbols for status and results.
Highlights key features like No Coding, Second-Chance sampling, and Bluetooth connectivity.
Read guides, check kit contents, and ensure correct test strips and control solution.
Lists common symptoms of hypoglycemia and hyperglycemia for better result understanding.
Step-by-step guide on obtaining a blood sample and applying it to the test strip.
Explains how to use Fasting, Before Meal, and After Meal markers to categorize results.
How to access and navigate stored blood glucose test results and meal markers.
Procedure to enter the settings menu via the Home screen and OK button.
Guides for adjusting the meter's time format, hour, minute, date format, and day/month/year.
Instructions on turning meter sound on/off and enabling/disabling the Meal Marker feature.
How to view target ranges and configure the smartLIGHT indicator for result feedback.
Steps to enable Bluetooth and put the meter into pairing mode for app connectivity.
Guidelines for storing, handling, and cleaning the meter to ensure longevity and performance.
Detailed instructions for cleaning and disinfecting the meter and lancing device using specific wipes.
Explanation of error codes (E1-E99) and recommended actions for resolving issues.
Presents system accuracy and precision results from clinical studies and testing.
Technical details of the meter including range, memory, battery, dimensions, and operating conditions.
Defines common symbols used on the product labeling for clear understanding.
| Type | Blood Glucose Meter |
|---|---|
| Display | LCD |
| Test Time | 5 seconds |
| Sample Size | 0.6 µL |
| Memory Capacity | 800 test results |
| Connectivity | Bluetooth |
| Battery Type | CR2032 |
| Operating Temperature | 10°C to 40°C |
| Measuring Range | 20 to 600 mg/dL |
| Operating Humidity | 10% to 90% RH |
| Storage Conditions | -20°C to 50°C |