6.9 Xover
IN_1: MENU:Xovr IIR
TYPL: Off
FRQL: 0100Hz
TYPH: Off
SLPL:24dB
FRQH:01000Hz
SLPH: 2 4dB
OUT_1: MENU:Xovr FIR
TYPL: Off
FRQL: 0100Hz
TYPH: Off
FRQH:01000Hz
In the input state, click to switch to IIR, in the output state, click again to switch to FIR.
TYPL:
The 3 available filter types for the low frequency crossover point (high pass) are:
Butterworth, Linkwitz Riley or Bessel.
FRQL:
The filter cut-off frequency for the low frequency crossover point (high pass) ranges
from 20 to 30kHz in either 1Hz steps or 1/36 octave steps. The frequency steps can
be selected in the System Menu. Please refer to page 17 for more details.
6.8 Delay
DELAY:
The maximum allowed delay is 62400 samples, with each sample approximately
10us (1/96k). The equivalent delay time is displayed on the right side of the
parentheses. The delay time unit can be set to ms, ft, or m in the system menu.
For more details, please refer to page 17. You can use cursor movement to quickly
adjust numbers
IN_1: MENU:Delay
DELAY: 00000 (000. 000ms)