6.10 Limiter
THRESH:
The limiter threshold ranges from -20 to +20dBu in 0.5dB steps.
ATTACK:
The limiter attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges
from 1 to 100ms in 1ms steps.
RELEASE:
The limiter release time can be set at 2X, 4X, 8X, 16X or 32X the attack time.
6.11
IN_1: MENU:Comp
THRESH :+20.0dBu
ATTACK :10ms
RELEASE:8X (80ms)
RATIO: 1:1
OUT_1: MENU:Limit
THRESH :+20.0dBu
ATTACK :10ms
RELEASE:8X (80ms)
In the input state, click to switch to Comp,
and in the output state click again to switch to Limit.
UP :
Move the cursor up.
Down :
Move the cursor downwards
Exit :
Exit to the Main Menu.
ENTER / SYSTEM :
Enter enters the System Menu from the mainmenu and is
used in the System Menu to proceedwith selected actions.