OverClocking Feature to initialize the default value. In Legacy Mode, setting a
global oset for the entire VF curve. In Selection modes, setting a selected VF point.
Ring Voltage Oset
Species the Oset Voltage applied to the Ring domain. is voltage is specied in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Oset Prex
Sets the oset value as positive or negative.
GT Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the voltage
selected will be applied over all operating frequencies. In Adaptive Mode the voltage
is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11.
GT Extra Turbo Voltage
Species the extra turbo voltage applied while GT is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
GT Voltage Oset
Species the Oset Voltage applied to the GT domain. is voltage is specied in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Oset Prex
Sets the oset value as positive or negative.
Uncore Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the voltage
selected will be applied over all operating frequencies. In Adaptive Mode the voltage
is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11.
Uncore Extra Turbo Voltage
Species the extra turbo voltage applied while SA Uncore is operating in turbo
mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
Uncore Voltage Oset
Species the Oset Voltage applied to the Uncore domain. is voltage is specied
in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Oset Prex
Sets the oset value as positive or negative.