58
ASUS X99-DELUXE II Series BIOS Manual
Chassis Fan 1-2 Profile
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust
depending on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan
operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis Fan 1-4 Prole to [Manual].
Chassis Fan 1-2 Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the Chassis Fan 1-2
temperature. The values range from 45°C to 75°C. The Chassis Fan 1-2
will operate at the maximum duty cycle when the temperature source is
higher than the limit.
Chassis Fan 1-2 Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum Chassis Fan 1-2 duty
cycle. The values range from 60% to 100%. When the temperature source
reaches the upper limit, the Chassis Fan 1-2 will operate at the maximum
duty cycle.
Chassis Fan 1-2 Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the Chassis Fan 1-2
temperature. The values range from 40°C to 75°C.
Chassis Fan 1-2 Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the Chassis Fan 1-2 middle duty cycle.
The values range from 60% to 100%.
Chassis Fan 1-2 Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the Chassis Fan 1-2
temperature. The values range from 20°C to 75°C. The Chassis Fan 1-2
will operate at the minimum duty cycle when the temperature source is
lower than the limit.
Chassis Fan 1-2 Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum Chassis Fan 1-2 duty cycle.
The values range from 60% to 100%. When the temperature source is
under the limit, the Chassis Fan 1-2 will operate at the minimum duty cycle.
Water Pump Control
This item allows you to set the water pump operating mode.
[Auto] Detects the type of water pump installed and automatically switches the
control modes.
[PWM Mode] Enables the Water Pump Control feature in PWM mode for 4-pin water
pump.
[DC Mode] Enables the Water Pump Control feature in DC mode for 3-pin water
pump.
[Disabled] Disables the Water Pump Control.

Related product manuals