Atag iC Economiser 27 Plus User Manual

Atag iC Economiser 27 Plus
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ATAG i Series Boiler Fault Finding 02/10/23.
(All models and generations).

Other manuals for Atag iC Economiser 27 Plus

Question and Answer IconNeed help?

Do you have a question about the Atag iC Economiser 27 Plus and is the answer not in the manual?

Atag iC Economiser 27 Plus Specifications

General IconGeneral
Boiler typeCombi
CH output27kW
DHW output27kW
Max working pressure3 bar
Dimensions (HxWxD)700x440x355 mm
Gas typeNatural gas
Warranty10 Years
MountingWall mounted
ERP efficiencyA
TypeCondensing

Summary

ATAG i Series 1st generation boiler fault finding

Outside sensor error

Outdoor sensor not present, short-circuited, broken, or outside specs.

Flow sensor error

Flow sensor T1 value out of range, indicating potential circulation issues.

Return sensor error

Return sensor T2 value out of range, indicating potential circulation issues.

Bus communication error

No signal from the One controller, indicating a communication fault.

No pump kick detected/Faulty pressure sensor

No pressure increase when pump runs, possibly due to air or sensor fault.

Safety temperature exceeded

Temperature rise is too fast, possibly due to sensor or circulation fault.

Maximum temperature exceeded

Possible sensor fault or circulation issue causing temperature limits to be exceeded.

Water pressure too high (>3 bar)

System water pressure exceeds 3.0 bar, often related to expansion vessel.

Water pressure too low (<0.8 bar to 0.5 bar) or no pump kick detected

Insufficient water pressure or pump not operating correctly.

lonisation current too low

Low ionisation level at maximum fan speed, indicating ignition issues.

ATAG i Series 2nd generation boiler fault finding

ATAG i Series 3rd generation boiler fault finding

Servicing the expansion vessel