INstallatION
Prior to connecting the drawer, ensure that all cables in your
home’s electrical system are of sufficient diameter to supply the
appliance properly. Your system should be protected by a 10-amp
fuse.
The power circuit should have a bipolar power failure mechanism with
contact gaps of at least 3 mm.
Complete all electrical connections before building in the appliance.
The drawer should be connected via a (normalised) power cable with
3 x 1 mm² conductors (1 phase + 1 N + earth) to single phase
220 - 240 V~ mains power, via a 1 phase + N + normalised earthing
CEI 60083 plug socket or in accordance with local installation
regulations. The earth wire (green/yellow) should be connected to the
appliance’s connector clamps and with the electrical system’s earth.
If the appliance is connected to a plug socket, this must remain
accessible after the drawer has been installed.
The warming drawer’s neutral conductor (blue wire) should be
connected to the mains power neutral conductor.