ATD-5850
3/16” AIR RIVETER INSTRUCTION MANUAL
SpeciĮcaƟons:
Nosepieces: 3/32", 1/8", 5/32", 3/16"
Rivet Capacity: 3/16”
Motor: 1/2 Hp
Air Inlet Thread NPT: 1/4”
Air Hose I.D. Size: 3/8” (10mm)
Avg. Air Consumption: 4 CFM
Air Pressure: 90-120 psi
Pulling Force: 1984.50 lbs.
California Prop 65 WARNING: This product contains chemicals including lead, known to the State of
California to cause cancer, birth defects, or other reproduĐƟve harm. Wash hands aŌer handling.
Question and Answer IconNeed help?

Do you have a question about the ATD AIR ATD-5850 and is the answer not in the manual?

ATD AIR ATD-5850 Specifications

General IconGeneral
BrandATD AIR
ModelATD-5850
CategoryRivet Tools
LanguageEnglish

Summary

Product Specifications

General Safety Warnings

Use Safety Equipment

Users and bystanders should use safety goggles, safety glasses, dust masks, respirators, non-skid safety shoes, etc.

Work Area and Personal Preparedness

Keep work area clean, uncluttered, well-lit, and avoid slippery floors. Dress properly and avoid distractions.

Safe Operating Practices

Do not operate if tired or under the influence of alcohol, drugs, or medication. Keep bystanders out of the work area.

Air Tools Specific Safety Warnings

Air Pressure Hazards

Air under pressure can cause severe injury. Never point an air tool at anyone or direct air at yourself or others.

Pre-Maintenance Safety Procedures

Turn off air supply and drain the hose before installing, removing, or adjusting accessories or performing maintenance.

Hose and Air Supply Safety

Hose and Fitting Integrity

Always check for damaged, frayed, or loose hoses and fittings. Replace defective parts immediately.

Hose Handling and Protection

Do not carry the tool by the hose. Protect the hose from sharp objects and heat.

Hose and Coupling Pressure Rating

Use air hose and couplings with a pressure rating at least 1-1/2 times the tool's maximum working pressure.

Air Supply Connection Safety

Do not depress the tool trigger/lever when connecting the air supply hose.

Trigger Safety and Tool Shutdown

Do not disable the trigger. Shut off air supply and drain line when not in use or for storage.

Typical Air Supply Installation and Maintenance

Air Supply Setup Diagram

Diagram illustrating typical air supply components: filter, regulator, oiler, hoses, and couplers.

Air Quality and Lubrication

Use clean, dry air. Drain tank daily, clean filter weekly. Lubricate air motor daily with quality air tool oil.

Product Unpacking and Initial Checks

Maintenance and Oil Addition

Hydraulic Riveter Oil Addition

Add hydraulic oil when the rivet is not broken after 5 pulls. Use quality hydraulic oil like Mobil DTE 10.

Riveter Head Maintenance

Turn off air supply. Disassemble riveter head, clean inner/assembly parts with a brush, oil parts, and reassemble.