9
Manual mode
SMART mode
Level
Level selected
Temperature
set
Comfort level
Energy-
saving level
1
57.5°C
--
++
2
62.5°C
-
+
3
67.5°C
=
=
4
72.5°C
(Recommended)
factory setting
(Recommended)
factory setting
5
75°C
++
--
- Activating/deactivating the child lock:
To activate the child lock, keep and depressed simultaneously for more than 3 seconds.
An active child lock is indicated by a box at the top right of the screen.
To deactivate the child lock, keep and depressed simultaneously for more than 3 seconds.
After a long period during which the unit has been switched off, the child lock may become deactivated.
- Reset:
The unit is reset by pressing the and buttons simultaneously (less than 1 second)
In the event of an error and once the source of the error has been resolved, it resets the error to activate normal mode.
In the event of normal operation, it resets the product to default factory settings.
- Anti-legionnaire’s disease function:
The anti-legionnaire’s disease function reduces the risk of bacteria developing in the water stored in the tank.
As soon as your water heater is correctly installed and operating, and regardless of the mode selected, a process will constantly monitor the water
temperature. Any time conditions are detected which could cause the development of bacteria, the water will automatically be heated to a
temperature above 65°C.