ACTA 4000 User Guide Getting started
9836 4171 01 2008-12 21 (136)
2. Select menu block Q.prog.
3. Select
Synchronize and press ENTER.
4. Select controller.
1 None
2 Other controller
Select tool type and insert input target torque.
For pulse tools, also insert filter frequency
For wrenches, select measurement strategy
Static installed torque
or
Peak (DD).
3 Focus2000/PF2000
4 DS/DL
Select
RS232 as type of communication.
For Focus2000/PF2000 with RS232 Communication, enter unit ID
when requested.
5 PF3000/PF4000
6 PowerMACS
Select
RS232 as type of communication.
5. Do the tightening operations.
The results from the controller and the transducer are displayed in the
Measurement dialog box after
each tightening. The controller display shows only the controller result.
Note: The DS/DL controller does not send a value as the torque tuning is made against the controller
target value.
6. Save and print the result.
Evaluate, and if applicable, calibrate the tool. See section Calibrating tools and equipment.
References
For details on Statistics and calculation of the parameters, see section Guide to statistics.
For instructions on how to calibrate, see section Calibrating tools and equipment
For inform
ation about printouts, see section Printouts from ACTA
For explanation of all m
enu items, see section Programming ACTA.