Programming ACTA ACTA 4000 User Guide
50 (136) 2008-12 9836 4171 01
ACTA 4000 dialog box
Sensitivity
List of torque sensors and their normal output.
No Name Bridge
sensitivity
Add. Req. voltage
supply
1 0,59 mV/V 0,59 mV/V Bridge resistance
700 Ω
10V
2 0,8 mV/V 0,8 mV/V Bridge resistance
700 Ω
10V
3 1,2 mV/V 1,2 mV/V Bridge resistance
350 Ω
10V
4 1,475 mV/V 1,475 mV/V Bridge resistance
350 Ω
10V
5 2,0 mV/V 2,0 mV/V Bridge resistance
350 Ω
10V
6 Flexible 0.2 to 3.0
mV/V
10V
7 Microtec 0 to 5 V 12
8 Crane -2.5 to + 2.5 V 10V
9 Staiger
Mohilo
-5 to + 5 V 12
Flexible sensitivity
When Flexible Sensitivity is selected above, this is the nominal output at
calibration torque.
Serial number
The serial number of the transducer (displayed in list). This is marked on
all tightening.
Comment
A string defining the transducer (displayed in list).
Calibration torque
This is the torque that correspond the positive bridge sensitivity voltage
in the table above.
Angle encoder
Number of pulses / 360 degree.
Scale factor
Scale factor on the gyro is proportional against the angle speed.
Unit is mV/degr/s
Gyro torsion factor
Bending factor on a wrench.
ACTA 3000 dialog box.
1. TTQAT media
The communication interface; RS232, USB, or Ethernet.
2. Client port
The port to which ACTA is listening for incoming Ethernet.
3. Server hostname
Host name for TTQAT server
4. Server IP address
TTQAT server IP address. Only used if ACTA must contact a specific
server with a message that it is connected.
5. Server port
The port ACTA is using to contact the TTQAT server.
Use this dialog box to set the parameters to the correct value for the transducer used. This information
should be found on the label of the transducer. If it is missing, contact the manufacturer.