2. A dismounted belt has to be replaced with a new one.
3. Take off the hood.
4. Loosen the applicable nuts.
5. Replace the belt.
6. Reassemble in reverse sequence.
7. Stretch the V-belts with the V-belt tension meter.
Refer to V-belt tensioning on page 73 for details.
GVS 630A
Tools required: Key 19 and 24.
1. Take off the hood. Loosen the applicable nuts.
2. Loosen the push rod.
3. Remove the V belts.
4. Reassemble in reverse sequence.
5. Stretch the V
-Belts with the V-belt tension meter.
7.6.7. V-belt tensioning
How to use the V-belt tension meter
The tension meter is a tool designed to check and retighten the Vbelts. It is
made of two sliding pipes with a graded spring inside.
Refer to Figure: Belt tensioning. Set the first O-ring at 1 mm (0.03 inch) (PIX)
on the millimetre scale or 25 inches of span, as shown in picture 3, and the
other Oring on position 0 on the Newton scale.
Install the tension meter as shown in picture 1, in the middle, halfway between
the Vbelt contacts point of the Vbelts and the two pulleys.
Push the Newton scale's black rubber down to reach a 10 mm (0.39 inch)
bending of the Vbelt as shown in pictures 2 and 4.
12/2021 - ©Atlas CopcoPage 736996022430_C
Maintenance

Other manuals for Atlas Copco GVS 16A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GVS 16A and is the answer not in the manual?

Atlas Copco GVS 16A Specifications

General IconGeneral
BrandAtlas Copco
ModelGVS 16A
CategoryWater Pump
LanguageEnglish

Related product manuals