Parameter Unit
GVS
16A
GVS
25A
GVS
40A
GVS
60A
GVS
100A
GVS
200A
GVS
220A
GVS
300A
GVS
470A
GVS
630A
Maximum inlet
pressure for water
vapour with big gas
ballast (or 2 GB)
mbar(a) N/A N/A N/A 60 60 50 40 70 40 60
torr
(mmHg)
N/A N/A N/A 45 45 37.5 30 52.5 30 45
Maximum water va-
pour pumping rate
vapour with stand-
ard gas ballast
kg/h 0.05 0.08 0.76 1 1.6 3.4 5 1.3 5 17
Note:
Lower temperatures are possible with reduced viscosity oil. This temperature range is defined by Pneurop for performance
conformity testing, but 8 °C is the critical point from the motor starting view point.
12/2021 - ©Atlas CopcoPage 416996022430_C