Compressor type GX7 GX11 GX7 GX11
Nominal motor power rating kW 7.5 11 7.5 11
Nominal motor power rating hp 10 15 10 15
Dryer power consumption at full
load, Full Feature units
kW 0.44 0.44 0.44 0.44
Dryer power consumption at full
load, Full Feature units
hp 0.59 0.59 0.59 0.59
Oil capacity l 3 3.2 3 3.2
Oil capacity US gal 0.8 0.84 0.8 0.84
Oil capacity Imp gal 0.65 0.7 0.65 0.7
Oil capacity cu.ft 0.1 0.11 0.1 0.11
Sound pressure level (according
to ISO 2151 (2004))
dB(A) 67 68 67 68
60 Hz 150-175 psi (under reference conditions)
Compressor type GX7 GX11 GX7 GX11
Frequency Hz 60 60 60 60
Maximum (unloading) pressure,
Pack
bar(e) 10.8 10.8 12.5 12.5
Maximum (unloading) pressure,
Pack
psig 157 157 181 181
Maximum (unloading) pressure,
Full-Feature
bar(e) 10.55 10.55 12.25 12.25
Maximum (unloading) pressure,
Full-Feature
psig 153 153 178 178
Nominal working pressure bar(e) 10.3 10.3 12 12
Nominal working pressure psig 149 149 174 174
Set-point, thermostatic valve ˚C 75 75 75 75
Set-point, thermostatic valve ˚F 167 167 167 167
Temperature of air leaving outlet
valve (approx.), Pack
•
Tank-mounted
˚C 38 43 38 43
•
Tank-mounted
˚F 100 109 100 109
•
Floor-mounted
˚C 60 66 60 66
•
Floor-mounted
˚F 140 151 140 151
Temperature of air leaving outlet
valve (approx.), Full-Feature
˚C 23 25 23 25
Temperature of air leaving outlet
valve (approx.), Full-Feature
˚F 73 77 73 77
Nominal motor power rating kW 7.5 11 7.5 11
Nominal motor power rating hp 10 15 10 15
Dryer power consumption at full
load, Full Feature units
kW 0.44 0.44 0.44 0.44
Dryer power consumption at full
load, Full Feature units
hp 0.59 0.59 0.59 0.59
Instruction book
68 2920 7054 00