Models OSC
145
Cold climate l/s 105 280 415 1035 1800 2410 3450 6895
Mild climate l/s 45 118 175 435 760 1020 1455 2910
Hot climate l/s 20 50 75 190 330 440 630 1260
Correction factors
For
operation in other than reference conditions, multiply the compressor capacity (FAD) with the appropriate
correction factors.
Running hours per
day
8 10 12 14 16 18 20 22 24
Correction factor 1.50 1.20 1.00 0.86 0.75 0.67 0.60 0.55 0.50
Separation performance
For an outlet oil carry-over of 10 mg/l instead of 15 mg/l, multiply the unit capacity by 2/3.