- 37 -
The second page contains engine related data.
Settings View
In the settings view the operator can view and change
(depending on the authorisation level) various
parameters.
Use the up and down navigation buttons to scroll
through the full list of settings.
Use the enter button to enter the selected submenu.
Use the back button to leave the entered (sub) menu.
Alarm View
In the alarm view the operator can view the various
alarms, actual and history.
Use the up and down navigation buttons to scroll
through the full list of alarms.
Use the left and right navigation buttons to scroll
through the different Alarm pages:
Fuel rate
Engine coolant temperature
Engine fuel temperature
Engine oil temperature
Engine inlet temperature
Engine boost pressure
Engine load
Engine rpm
Rpm setpoint
Ambient temperature
ECU
READY TO LOAD
1399RPM69h
Fuel rate 4 l/h
Engine coolant temp. 87°C
Engine inlet temperature 30°C
Engine oil pressure 2.6 bar
Engine fuel pressure 4.1 bar
Engine boost pressure 1.2 bar
40%
SETTINGS
LOADED
1300RPM 22.4bar1286h
1000 GENERAL SETTINGS
2000 DIGITAL INPUTS
3000 VOLTAGE INPUTS
4000 TEMPERATURE INPUTS
5000 RELAY OUTPUTS
5300 SEMICONDUCTOR OUTPUTS
6000 SYSTEM SETTINGS
40%
General Alarms
Alarm Log
DM1 List
Event Log
DM2 List
ALARMS
LOADED
1300RPM 22.4bar1286h
3450 BATTERY LOW ALARM
2070 COOLANT LEVEL LOW
3010 FUEL LEVEL LOW
ECU DM1 LIST
ECU DM2 LIST
EVENT LOG LIST
ALARM LOG LIST
40%