- 37 -
Designation XATS 68 Kd XAS 78 Kd XAS 88 Kd XAS 68 G Kd
Minimum effective receiver pressure bar 2222
psi 30303030
Maximum effective receiver pressure,
compressor unloaded
bar 13.5 8.8 8.8 8.8
psi 200 125 125 125
Maximum ambient temperature
at sea level
without aftercooler °C 50 50 50 50
°F 122 122 122 122
with aftercooler °C 45 45 45 45
°F 113113113113
Minimum starting temperature °C -10 -10 -10 -10
°F 14 14 14 14
Minimum starting temperature, with coldstart equipment °C -20 -20 -20 -20
°F -4 -4 -4 -4