1
INSTRUCTIONS FOR
INSTALLATION AND MAINTENANCE
OF HYDRA SELF-CLEANING FILTERS
Dear Customer,
Thank you for choosing this product manufactured in Italy by ATLAS FILTRI S.r.l.,
assembled and marketed in the USA and Canada by ATLAS FILTRI NORTH AMERICA,
LLC. The filter has been designed and manufactured in Italy using over 40 years of
expertise in the industry.
Copyright: This manual of instructions cannot be reproduced, in whole or in part, in any form (including
its recording, digitalization or photocopying) without the written consent of Atlas Filtri North America,
LLC.
CONFORMITY CERTIFICATES
ATLAS FILTRI FILTER HOUSINGS COMPLY WITH THE
FOLLOWING INTERNATIONALLY ACCEPTED STANDARDS:
HYDRA self-cleaning filter series with plastic threaded
connections, as components certified by IAPMO RT to
NSF/ANSI 42, 61, 372 - lead free, CSA B483.1. In compliance
with Drinking Water Treatment Units regulations, USA and
CANADA.
AB9210055 - R05-11/17. Subject to change without notice
TABLE OF CONTENTS
1 Safety Alert Symbols 2
2 General Information 2
3 Personnel’s Qualification 2
4 Precautions, Warnings 2
5 Installation 3
6 Start Up 4
7 Use 4
8 Spare Parts 5
9 Maintenance 5
10 Troubleshooting 7
11 Filter and Cartridge Disposition 7
12 LIMITED WARRANTY 7
USA & CANADA
Contact:
ATLAS FILTRI North America LLC
1068 North Farms Road Bldg. #3 - Wallingford, CT 06492, USA
Phone +1(203)284-0080 - Fax +1(203)294-9226
e-mail: atlasfiltrinorthamerica@atlasfiltri.com
A Company of the Atlas Filtri Group.
www.atlasfiltri.com
Atlas Filtri S.r.l.
Headquarter and
production in Italy

Other manuals for Atlas Filtri HYDRA

Questions and Answers

  • K
    Karen MackAug 18, 2025
    What to do if unfiltered water runs from faucets with Atlas Filtri HYDRA?
    • K
      kosborneAug 18, 2025
      If unfiltered water is running from the faucets when using your Atlas Filtri Water Filtration System, it could be due to several reasons. The cartridge might be broken, the spring could be damaged, or the cartridge gasket might be ruined. Alternatively, the bypass valve may be open. To resolve this, try replacing the cartridge, replacing the spring, or replacing the cartridge gasket. Also, ensure that you close the bypass valve.
  • B
    Bradley ClarkAug 20, 2025
    Why water does not run from faucets with Atlas Filtri HYDRA?
    • J
      Jacob WoodAug 20, 2025
      If water isn't running from your faucets when using your Atlas Filtri Water Filtration System, it could be due to a clogged cartridge, a broken bowl, or closed cut-off valves or bypass. To fix this, clean the cartridge following the maintenance procedure. If the bowl is broken, replace it along with the o-ring. Also, ensure that the cut-off valve or bypass is open.
  • T
    tammyfergusonAug 22, 2025
    How to fix water leaks between the filter head and bowl in Atlas Filtri Water Filtration Systems?
    • D
      Donna WilsonAug 23, 2025
      If you notice water leaking between the filter head and bowl of your Atlas Filtri Water Filtration System, the bowl O-ring is likely ruined. The solution is to replace the O-ring.
  • N
    Nicole JonesAug 26, 2025
    What to do if water leaks from connections in Atlas Filtri HYDRA Water Filtration Systems?
    • C
      cynthia73Aug 26, 2025
      If water is leaking from connections between pipes or from the sides of your Atlas Filtri filter, it's likely due to insufficient sealing tape. To resolve this, add a few more turns of sealing tape to the connections.
  • R
    Richard KelleyAug 28, 2025
    How to fix the cartridge if it does not clean during self-cleaning operation in Atlas Filtri HYDRA?
    • K
      katherine31Aug 28, 2025
      If the cartridge in your Atlas Filtri Water Filtration System isn't cleaning during the self-cleaning operation, it could be due to insufficient pressure in the bowl or the cartridge not being correctly positioned. Check the drain pipe for any pinches or bends and remove them. Rotate the cartridge clockwise or counter-clockwise to ensure it moves vertically without strain in the bowl.
  • Z
    zrodriguezAug 30, 2025
    What to do if water leaks between the bowl and drain valve in Atlas Filtri HYDRA?
    • J
      james31Aug 30, 2025
      If water leaks between the bowl and drain valve of your Atlas Filtri Water Filtration System, it's likely that the drain valve gasket is damaged. Replace the gasket to resolve this issue.
  • M
    Michael IngramSep 2, 2025
    What to do if water leaks from Atlas Filtri HYDRA connections?
    • B
      Bobby KellySep 2, 2025
      If water leaks from connections between pipes and from the sides of the filter IN/OUT ports of your Atlas Filtri Water Filtration Systems, it's likely due to insufficient sealant. Try adding a few turns of sealing tape and tighten the fittings until they are snug.
  • K
    Kara CurrySep 4, 2025
    Why is no water running from my Atlas Filtri Water Filtration Systems?
    • L
      Luke RileySep 4, 2025
      If water is not running from the faucets connected to your Atlas Filtri Water Filtration Systems, several issues could be the cause: * The cartridge may be clogged. In this case, clean the cartridge following the maintenance procedure. * The sump might be broken. If so, replace the sump and o-ring. * The by-pass could be closed. Open the closed cut-off valve or by-pass.
  • D
    David RichardsonSep 6, 2025
    What to do if unfiltered water runs from Atlas Filtri HYDRA Water Filtration Systems?
    • V
      Victoria KingSep 7, 2025
      If unfiltered water runs from faucets connected to your Atlas Filtri Water Filtration Systems, it could be due to a few reasons: * The cartridge may be broken, so replace it. * The spring may be broken, so replace it. * The cartridge gasket may be damaged, so replace it.
  • M
    Michelle LambertSep 9, 2025
    How to fix water leaks between filter head and sump in Atlas Filtri HYDRA Water Filtration Systems?
    • D
      Dustin BurnsSep 10, 2025
      If water leaks between the filter head and sump of your Atlas Filtri Water Filtration Systems, the sump o-ring is likely damaged. Replace the o-ring and lubricate it.

Summary

Safety Alert Symbols

Warning and Caution Symbols

Defines potentially hazardous situations and alerts to unsafe practices.

Notice Symbols

Alerts users to pertinent facts and conditions.

General Information

Product Identification and Labels

Details on product labels, serial numbers, and working parameters.

Personnel Qualification

Precautions and Warnings

Installation

Installation Guidelines and Connections

Covers pipe connections, sealant use, and avoiding stress.

Drain Kit and Hose Installation

Instructions for installing the drain kit and connecting the rubber hose.

Start Up

Start-Up Procedure and Air Release

Steps for initial filter operation, including air release from the system.

Filter Use

Filter Usage Recommendations

Guidelines on water quality, temperature, pressure, and protection from environmental factors.

Accessories and Spare Parts

Maintenance

Routine Back-Wash Cleaning

Procedure for cleaning the filter cartridge using the drain valve.

Additional Cartridge Cleaning

Steps for deeper cleaning when routine methods are insufficient.

Troubleshooting

Common Malfunctions and Remedies

Table detailing issues, causes, and solutions for filter operation.

Filter Housing and Cartridge Disposal

Limited Warranty

Warranty Terms and Exclusions

Details the warranty period, what's covered, and common exclusions.

Limitations and Liability

Defines liability limits and exclusions for Atlas Filtri North America, LLC.

Atlas Filtri HYDRA Specifications

General IconGeneral
BrandAtlas Filtri
ModelHYDRA
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals