Chapter 5 Property description
5.1 Property description
Āƻā: The parameter can be modified when the 9)' is in either stop or running state.
Āhā: The parameter can not be modified when the 9)' is in the running state.
* ”: The parameter is factory parameter and can not be modified.
5.2 Standard Function Parameters
Function
Code
Parameter
Name
Setting Range
Unit
Default
Prop
erty
Group P0: Standard Function Parameter
P0.00 Control mode
0˖V/F control
1˖Sensorless vector
control(SVC)
2
˖
Sensor vector control(FVC)
1
P0.01
Main frequency
source 1 selection
0˖Digital setting 1(P0.02ˈ
UP/DOWN can
modify,non-retentive at power
failure)
1˖Digital setting 2(P0.02ˈ
UP/DOWN can
modify,retentive at power
failure)
2˖VI analog setting˄VI-GND
˅
3˖CI analog setting˄CI-GND
˅
5˖Pulse setting
6˖Multi-reference
7˖Simple PLC
8˖PID
9
˖
485 communication
1
P0.02
Setting running
frequency
P0.07lower limit frequency
P0.06 upper limit frequency
0.01Hz 50.00Hz ż
P0.03
Command source
selection
0˖Operation panel control
(LED off)
1˖Terminal control˄LED on
˅
2˖Communication control
˄LED blinking˅
1 0 ż
P0.04 Rotation direction
0˖Same direction
1
˖
Reverse direction
1 0 ż
GK3000 User Manual