E4: Over-current Error
If E4 error code is reported continuously,
it is considered to be hardware fault of
controller.
Contact ATOMI help center or authorized
vendors for after-sales services.
Check whether the battery voltage is too
PS[ FIPS[  ZSPXW VITPEGI E RI[
battery to test, if the error disappears,
charge the undervoltage battery.
E5: Under Voltage Protection E6: Over Voltage Protection
It means the battery voltage is too high.
Avoid sudden brake or going down hill, it
will return to normal after battery power
goes down.
E7: Hall Motor Error
Check whether the hall cable is connected
properly.
If the cable is connected properly but
the error is still reported, the motor hall is
damaged and needs to be repaired.
Check if the phase cable is connected
properly.
Replace the controller to test, if the error
code disappears, the controller is the
issue.
Replace the motor to test, if the error
code disappears, the motor is the issue.
E8: Motor Phase Loss E9: Controller Error
If E9 is reported continuously, it means
the controller is faulty.
Restart the scooter for a few times, if the
error code is still reported, please
contact ATOMI support center or ATOMI
authorized vendors to replace the
controller.
18