4 1
Operation Instructions
Power on/off:
Press“ ” to power the meter on/off.
Data Hold:
Whilst in measurement mode, press ”, the LCD display will clearly
display “HOLD” which indicates the data is frozen, to release the held
reading. Press the “ ” button again the release the reading.
MAX/MIN:
Whilst in measurement mode, press“ to cycle through the maximum
or minimum recorded light levels. The LCD display will clearly display
“MAX”, or “MIN” to indicate the displayed value. Press and hold “ to
exit MIN/MAX mode and return to normal measurement mode.
Lux / Fc:
With the meter turned on, press “ ” to toggle between measurement
units, Lux and Foot-candles.
°C / °F Mode:
Whilst the meter is turned off, press and hold ” and press “ ”. The
unit will power on with the temperature unit (°C/°F) toggled.
Auto Power Off
Whilst the meter is turned off, press and hold ” and press “ ”. The
unit will turn on with the auto power off feature toggled off.
Note: If the icon is displayed, the auto power off feature is enabled.
Additional Notes
1) Recommended recalibration cycle: 1 year.
2) Remove the battery when the meter is to be stored for long periods of time to avoid
battery leakage.
3) When the battery is lowthe low battery indicator will appear.
A new battery is needed.
4) Do not store or operate the meter in high temperature or humidity.
5) Wind blowing across the microphone increases the noise measurement. Use the
supplied windscreen to cover the microphone when appliance.
6) Keep the microphone dry and avoid severe vibration.
This unit complies with EMC
ATP INSTRUMENTATION LTD
THE ONE STOP INSTRUMENT SHOP
WWW.ATP-INSTRUMENTATION.CO.UK
Sales: 01530 566800 Technical: 01530 566804
UNIT 22 Tournament Way, Ashby-De-La-Zouch, Leicestershire, LE65 2UU
MINI COLOUR LCD LIGHT METER
MT-912
USER MANUAL
Important Safety Notice
Read the following safety information carefully before attempting to operate or service the
meter. Use the meter only as specified in this manual; otherwise, the protection provided by
the meter may be impaired.
Environmental Operating Conditions
Humidity:
90% RH (Non-condensation)
Operating temperature:
-20 to 60°C / -4 to140°F
Maintenance
Repairs or servicing not covered in this manual should only be performed by qualified
personnel.
Wipe the unit with a dry soft cloth. Do not use abrasives or solvents on this instrument.
Question and Answer IconNeed help?

Do you have a question about the ATP Electronics MT-912 and is the answer not in the manual?

ATP Electronics MT-912 Specifications

General IconGeneral
BrandATP Electronics
ModelMT-912
CategoryMeasuring Instruments
LanguageEnglish

Summary

Operation Instructions

Basic Operations

Covers powering on/off, data hold, and MAX/MIN functions.

Unit and Mode Settings

Details switching between Lux/Fc units and toggling °C/°F mode.

Auto Power Off

Instructions for enabling or disabling the auto power off feature.

Safety and Conditions

Important Safety Notice

Crucial safety information to be read before operating or servicing the meter.

Environmental Operating Conditions

Specifies the recommended humidity and operating temperature ranges.

Maintenance

Instructions for cleaning and servicing the instrument.

Product Details

Application

Details the intended uses and environments for the light meter.

Features

Lists the key characteristics and functionalities of the light meter.

Specification

Technical specifications including measuring range, resolution, and accuracy.

Meter Description

Identifies and labels the physical components of the light meter.

LCD Display Description

Explains the icons and readings shown on the light meter's LCD screen.

Accessories

Lists the items included with the light meter.