Literature number 32472
hydro flame
AFL Series Furnaces Models
AFLD35, AFLD40
AFLA35, AFLA40
Technical Installation Manual
Atwood Mobile Products
1120 North Main Street • Elkhart, IN 46514
USA & Canada : 1-866-869-3118
Internet: http://www.atwoodmobile.com
English, Français (et Canada)
This instruction manual is for use by an authorized service technician
to install an Atwood hydro flame furnace. Should you require
further information, contact your dealer or Atwood Mobile Products
LLC.
This furnace design has been certified for installation in recreation
vehicles as a MSP Category III furnace. Follow this installation
instruction to insure safe operation of the furnace. Failure to install
furnace according to this installation instruction nullifies the furnace
warranty.
TO THE INSTALLER: LEAVE THIS MANUAL WITH THE
APPLIANCE.
TO THE CONSUMER: RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
Effective 8/15
WARNING
Installation of this appliance must be made in accordance with the
written instructions provided in this manual. No agent, representative
or employee of Atwood or other person has the authority to change,
modify or waive and provision of the instructions contained in this
manual.
WARNING
Avoid possible injury or death
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to the
installation instructions and/or owner’s manual provided with this
appliance. A qualified installer, service agency or the gas supplier must
perform installation and service.
CRITICAL INSTALLATION WARNINGS
DO NOT install furnace on material that restricts return air, like
carpet or any soft material such as vinyl.
DO NOT install furnace where clearance to combustibles cannot be
maintained.
DO NOT modify furnace or intake and exhaust vent in any way.
DO NOT alter furnace for a positive grounding system.
DO NOT hi pot furnace unless electronic ignition system (circuit
board) has been disconnected.
DO NOT use battery charger to supply power to DC model furnace
even when testing.
DO NOT use 120-volt AC current with DC models.
DO NOT use furnace cabinet area as a storage compartment.
DO NOT vent furnace with venting system serving another
appliance.
DO NOT vent furnace to an outside enclosed porch area.
DO NOT use for temporary heating of buildings or structures under
construction.
Protect building materials from degrading from flue gas exhaust.
Protect furnace electrical components from water.
Compartment must be closed when operating unit.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
DO NOT use this furnace if any part has been under water.
DO NOT use petroleum or citrus type cleaner on plastic parts, as
damage may occur.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WARNING
Be sure the furnace and all ignition systems are “off” during any type of
refueling and while vehicle is in motion or being towed.
WARNING
Avoid possible injury or
death
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety
hazards obey all safety messages following these symbols
CAUTION
Avoid possible injury
and/or property damage
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
Extinguish any open flame.
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container or
source.
Do not touch any electrical switch, or use any
phone or radio in the vehicle.
Do not start the vehicle’s engine or electric
generator.
Contact the nearest gas supplier or qualified
service technician for repairs.
If you cannot reach a gas supplier or qualified
service technician, contact the nearest fire
department.
Do not turn on the gas supply until the gas
leak(s) has been repaired.
A qualified Service Technician
Service Center or gas supplier must perform
installation and service.