EasyManua.ls Logo

Atwood G10-2 - User Manual

Default Icon
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.atwoodmobile.com or call
574-264-2131 to have a Service Center List mailed.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
CAUTION
avoid possible avoid possible
injury or death injury and/or property damage
Installation and service must be performed by a qualified Service
Technician, Service Center, OEM or Gas Supplier.
WATER HEATER MODEL IDENTIFICATION
............................................
1
DIMENSIONS
..........................................................
1
WEIGHT
................................................................
1
SAFETY INFORMATION
..................................................................
2-4
Water Heater
GENERAL INSTALLATION
..............................................
2-3
Electronic Ignition wiring installation
Pilot Relight wiring installation
Heat Exchanger
Combination Gas/Electric
Water Heater
PILOT OPERATION
......................................................
3-4
Electronic Ignition
Pilot Relight
Combination Gas/Electric
Water Heater
MAINTENANCE
..........................................................
4-5
Electronic Ignition
Electric
FIGURES
1-11 ............................................................................
6
WIRING DIAGRAMS
........................................................................
7
PART IDENTIFICATION
..................................................................
8-9
Water Heater
WARRANTY
..............................................................
16
EXPLANATION OF MODEL NUMBER
(
EXAMPLE
)
G C H 6 AA - 8 E/P
Electronic Ignition or Pilot Relight
Revision (
NUMBER
)
Heating Element (
SCREW
-
IN OR BOLT
-
ON
)
4 - 6 - 10 gallon capacity
Engine Heat Exchange
Combination Gas and AC Electric
Gas (
PROPANE
)
- IF YOUR MODEL NUMBER IS NOT LISTED-
Older revision numbers may be 3, 4, 6, 7, 8 or 9 (_ _ _ _ _ - X _)
Regardless of your revision number the current instructions are still generally
applicable to your unit. If you have questions contact your dealer, an Atwood
Service Center or the Atwood Service Department.
MODEL NUMBER CLARIFICATION
TYPE
4
GAL
6
GAL
10
GAL
Pilot Ignition G4-7 G6A-7 GC6AA-8P G10-2 GC10A-2
GC6AA-8 GH6-7 G10-2P GC10A-2P
Electronic Ignition G6A-8E GCH6A-9E G10-3E GCH10A-3E
GC6AA-9E GH6-8E GC10A-3E GH10-3E
Pilot Relight P
IN MODEL
# -
SEE MODEL CLARIFICATION ABOVE
Heat Exchange H IN MODEL # - SEE MODEL CLARIFICATION ABOVE
Electronic Ignition E IN MODEL # - SEE MODEL CLARIFICATION ABOVE
Combination Gas/Electric C IN MODEL # - SEE MODEL CLARIFICATION ABOVE
DIMENSIONS
SHIPPING WT.
ALL MODEL
WIDTH HEIGHT
6
GALLON
16˝ 12.5˝ 6
GALLON
25 lbs
10
GALLON
16˝ 15.5˝ 10
GALLON
32 lbs
ENGLISH, FRANCAIS
(et Canada)
•Installation •Operation •Maintenance
Effective 11/19/07
LITERATURE NUMBER
MPD 93756
L.P. GAS
WATER HEATER
4 - 6 - 10 GALLON
9
WARNING
FIRE OR EXPLOSION
• If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate
ALL
persons from vehicle.
• Shut off gas supply at gas container or source.
DO NOT
touch any electrical switch, or use any phone or
radio in vehicle.
DO NOT start vehicle’s engine or electric generator.
• Contact nearest gas supplier or qualified Service Technician
for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
DO NOT turn on gas supply until gas leak(s) has been
repaired.
http://waterheatertimer.org/Atwood-water-heater-resources.html

Other manuals for Atwood G10-2

Question and Answer IconNeed help?

Do you have a question about the Atwood G10-2 and is the answer not in the manual?

Summary

SAFETY ALERT SYMBOLS

FIRE OR EXPLOSION WARNING

WHAT TO DO IF YOU SMELL GAS

Step-by-step instructions for responding to a gas leak.

GENERAL INSTALLATION

CRITICAL INSTALLATION WARNINGS

GENERAL INSTALLATION PROCEDURE

PRESSURE-TEMPERATURE RELIEF VALVE

WIRING INSTRUCTIONS

ELECTRONIC IGNITION AND PILOT RELIGHT WIRING

Instructions for wiring electronic ignition and pilot relight systems.

OPERATION PROCEDURES

HOW TO OPERATE YOUR WATER HEATER

Instructions on how to operate the water heater.

CONSUMER SAFETY WARNINGS

SCALDING INJURY WARNING

MAINTENANCE AND CARE

PRESSURE-TEMPERATURE RELIEF VALVE

Information on the P/T relief valve and restoring air gap.

WIRING DIAGRAMS

Summary

SAFETY ALERT SYMBOLS

FIRE OR EXPLOSION WARNING

WHAT TO DO IF YOU SMELL GAS

Step-by-step instructions for responding to a gas leak.

GENERAL INSTALLATION

CRITICAL INSTALLATION WARNINGS

GENERAL INSTALLATION PROCEDURE

PRESSURE-TEMPERATURE RELIEF VALVE

WIRING INSTRUCTIONS

ELECTRONIC IGNITION AND PILOT RELIGHT WIRING

Instructions for wiring electronic ignition and pilot relight systems.

OPERATION PROCEDURES

HOW TO OPERATE YOUR WATER HEATER

Instructions on how to operate the water heater.

CONSUMER SAFETY WARNINGS

SCALDING INJURY WARNING

MAINTENANCE AND CARE

PRESSURE-TEMPERATURE RELIEF VALVE

Information on the P/T relief valve and restoring air gap.

WIRING DIAGRAMS

Atwood G10-2 Specifications

General IconGeneral
ModelG10-2
TypeGas
Capacity10 gallons
Dimensions16-1/4" H x 12-3/4" W x 20-1/2" D
Weight33 lbs (empty)
Fuel TypePropane
Input BTU12, 000 BTU
Water Capacity10 gallons

Related product manuals