F. Press OK or leaving no key pressed for 15
seconds, the thermostat will return to normal
operation mod.
Note: Programs 0, 1, 2, 3, 4, 5 are preset
programs. "A" and "B" cannot be used to edit them.
But "h" key is still active.
2.10 Manual Override
Method no. 1:
Press "A" to select comfort temperature. Press "B"
to select economy temperature. The current
temperature mode will be overrode until the next set
point of the program comes. Press OK to clear
override.
Method no. 2:
Press "A" or "B" and hold for 2 seconds. "01" will
apear on the LCD. It means that manual override
will be forced for one hour. The number of hours
(from 1 to 24) can be set by pressing/holding the
button.
PROG
0
6
12
18
24
0
c
Ni Po Wt Śr Cz Pt So
heating device
AURATON
2005 RX Plus
AURATON
2005 TX Plus
reciver radio signal
temperature controller
transmitter
AURATON 2005 TX RX Plus - Installation
38
3. Installation instructions
AURATON 2005 TX RX Plus
Programmable Temperature Controller AURATON
2005 TX Plus is almost the same product as
AURATON 2005. The only difference is way of
transmitting on/off signal. AURATON 2005 TX Plus
uses radio waves. That eliminates wires between
AURATON 2005 TX Plus and controlled device.
Receiver of radio waves is module called AURATON
2005 RX Plus. Range of AURATON 2005 TX Plus
is very high but depends on materials that house is
made of. AURATON 2005 TX Plus with AURATON
2005 RX Plus module is capable to hold range of
over 100mtrs outdoor and up to 30mtrs indoor.
EN