INSTALLATION
&
OPERATING
INSTRUCTIONS
The Australian
Gas Association
Approval No. 4553/AG103
Australian Patent
PN 200110001S
Effective January 2003
PLEASE KEEP THESE
INSTRUCTIONS FOR
FUTURE REFERENCE
Aurora
CLIMATE SYSTEMS
A.B.N. 43 108 083 987
Model: IS100
Model: IS200
Model: FS100
Model: FSP100
Model: FSC100
Serial Number: B.D. Number:
Question and Answer IconNeed help?

Do you have a question about the Aurora Archer IS100 and is the answer not in the manual?

Aurora Archer IS100 Specifications

General IconGeneral
Remote ControlYes
ColorBlack
ModelArcher IS100
Voltage120V
Flame EffectYes
ThermostatYes
TimerYes
Safety FeaturesOverheat Protection
MaterialMetal

Summary

To the New Owner

Owner Information and Warranty Program

Details for new owners on warranty registration, qualified installer requirements, and contact information.

Safety Precautions and Warnings

General Safety Guidelines

Crucial safety instructions, warnings on improper installation, and gas safety advice.

Safety Labels and General Specifications

Appliance Safety Labels and Warnings

Identifies safety labels and crucial 'DO NOT' warnings for safe operation and maintenance.

Technical Specifications Overview

Summary of key technical specifications including gas type, consumption, and electrical details.

Model Specific Specifications: FS101/P200 and FSC100

FS101/P200 Model Details

Detailed technical specifications and diagrams for the FS101/P200 model.

FSC100 Model Details

Detailed technical specifications and diagrams for the FSC100 model.

Model Specifications: FS100

FS100 Model Details

Detailed technical specifications and diagrams for the FS100 model.

Model Specifications: IS100

IS100 Model Details

Detailed technical specifications and diagrams for the IS100 model.

Model Specifications: IS200

IS200 Model Details

Detailed technical specifications and diagrams for the IS200 model.

Installation Instructions

General Safety Information

Key safety guidelines and requirements for installing the Archer Gas Log Space Heater.

Clearance to Combustibles

Specifies required clearances for freestanding and insert models to combustible materials.

Log Installation Procedure

Step-by-step guide for installing the gas log set, including handling fragile ceramic logs.

Log Set Diagram and Installer Notes

Diagram of the log set components and important notes for installers regarding log placement and gas pressure.

Main Logs and Burner View

Side view diagram illustrating the placement of main logs and burners.

Fluing Requirements

Details on approved co-axial and single flue pipe installations and configurations.

Flue Kit Components

Single Flue Kit Components

List and diagram of components included in the single flue kit for installation.

Co-Axial Flue Kit Components

List and diagram of components included in the co-axial flue kit for installation.

Flue Installation Methods

External Wall Installation (Co-Axial Flue)

Instructions for installing the heater with a co-axial flue kit through an external wall.

Pedestal Installation (Co-Axial Flue)

Instructions for installing a freestanding model with a pedestal using a co-axial flue kit.

Insert Model Installation (Co-Axial Flue)

Instructions for installing insert models with a co-axial flue in an exterior masonry fireplace.

Freestanding Unit Installation (Single Flue)

Guidance on correct and incorrect installation of freestanding units with single 40mm PVC flue pipe.

Internal Wall Installation (Single Flue)

Instructions for freestanding models installed through an internal wall using single 40mm PVC flue pipe.

Side Wall Installation (Horizontal Flue)

Instructions for horizontal single flue side wall installations using 40mm PVC flue.

Under Floor Installation (Single Flue)

Guidance for internal wall under floor installations using 40mm PVC flue, including water trap prevention.

Created Fireplace Model IS100/IS200 Installation

Installation details for IS100/IS200 models in created fireplaces, internal and external wall applications.

Flexible Flue Kit for Insert Models

Details on the standard flexible flue kit supplied for IS100/IS200 fireplace insert installations.

IS100 Fireplace Insert (Flexible Flue)

Specific installation guide for IS100 fireplace inserts using the Aurora flexible flue kit.

Optional Remote Control Thermostat

Remote Control Installation and Operation

Instructions for installing and operating the optional remote control thermostat and its features.

Remote Receiver and Flame Display Wiring

Wiring diagram and instructions for installing the remote receiver and front flame display button.

Gas Connection and Supply

Gas Connection Procedure

Step-by-step guide for connecting the gas supply line to the heater, ensuring proper routing.

Gas Valve Pressure Adjustment

Procedure for checking and adjusting gas valve pressure for optimal burner performance.

Wiring Diagram

Comprehensive wiring diagram for the Archer 2004 model, showing component connections.

Safety Screen Installation

Main Door Safety Screen Installation

Instructions for fitting the safety screen to the main door to prevent burns and ignition.

Fireplace Insert Surround Installation

Heater Surround Assembly

Guide for assembling and installing the fireplace insert surround.

Optional Pedestal Assembly

Pedestal Assembly Installation

Instructions for installing the optional pedestal assembly for the heater.

Automatic Humidifier Operation

Humidifier Function and Indicators

Explanation of the automatic humidifier's function, condensate collection, and LED indicators.

Operating Instructions Checklist

Pre-Operation Checklist

A comprehensive checklist to ensure safe and correct operation before starting the appliance.

Continued Operating Checklist

Further checks for log placement, polarity, panel security, and readiness for lighting.

Lighting Instructions

Burner Selection and Ignition Sequence

Guide to selecting burner settings, LED sequence, and safe ignition procedures.

Fan Operation and Shutdown

Convection Fan Operation

Details on the 3-speed convection fan's automatic operation, speed control, and temperature response.

Heater Shutdown Procedure

Instructions for safely shutting down the heater and the expected fan behavior during cooling.

Operating Faults and Curing

Over Temperature Cut Out

Explanation of the over-temperature cut-out feature and lock-out mode.

Paint Curing - First Firing

Procedure for the initial burn-in to cure the paint and initial smoke/odour expectations.

Troubleshooting and Resetting

Common Operating Faults

Identifies common causes of operating problems and the need for qualified personnel.

Resetting the Heater

Steps for troubleshooting common issues and resetting the heater after a shutdown event.

Maintenance

Routine Maintenance Schedule

Recommendations for annual maintenance, log placement, fan, and heat exchanger care.

Log Placement and Fan Maintenance

Guidance on log placement, replacement, and maintenance of the main convection fan.

Heat Exchanger Cleaning

Importance of inspecting and cleaning the heat exchanger for optimal performance.

Door and Glass Care

Cleaning and Maintenance of Doors

Instructions for cleaning gold/chrome plated doors and the main door glass.

Glass Replacement Procedure

Information on replacing the high-temperature safety glass if it breaks.

Component Specifications

Flame Safeguard System Specs

Technical specifications for the automatic control flame safeguard system.

Complete Unit Warranty

Warranty Coverage and Periods

Details on warranty periods for heat exchanger, fan, and other parts, and the Aurora warranty program.

Warranty Conditions and Exclusions

Outlines conditions, exclusions, and qualifications for warranty claims, including installation requirements.

Warranty Exclusions and Limitations

Further exclusions for modifications, incorrect installation, misuse, and consequential damages.

Specific Warranty Non-Applicabilities

Lists specific items and situations not covered by the warranty, such as glass breakage and customer service charges.