9-18
FITTED EQUIPMENT
Electrical operation
To start the refrigerator press the mode
button (1) for 2 seconds. The LED of the
previously selected operating mode will
illuminate.
Change the operating mode by pressing the
mode button (1) again, and the appropriate
indicator
LED (6) will illuminate.
Gas operation (LPG)
Prior to starting the refrigerator in gas mode:
• Open the gas cylinder valve
• Open the isolation valve inside the
vehicle for gas supply to the refrigerator
Press the mode button (1) several times until
the indicator LED (6) shows the gas flame.
The ignition process is then activated
automatically. Note that the ignition system
will make 2 attempts with 25 seconds interval
to light. If repeated attempts fail to start the
operation, a fault is indicated (please refer to
troubleshooting section).
Temperature setting
Select the desired cooling department
temperature by pressing button 2, and the
LED display (7) is illuminated. The scale
starts with MIN position at the bottom LED
position (small crystal = highest temperature)
and climbs up to MAX position at the upper
LED position (large crystal = lowest
temperature). Note the temperature levels do
not relate to absolute temperature values.
The refrigerator’s performance is influenced
by ambient temperatures. Please select the
medium temperature setting for ambient
temperatures between +15
o
C and + 25
o
C.
For temperatures below +10
o
C winter covers
should be fitted to the outside vents.
1 Power on switch / Energy selector switch
(MODE).
2 Temperature selection.
3 Door opening (only when equipped with
electrical door lock).
4 Indicator LED failure.
5 Indicator LED door lock (optional).
6 Indicator-LED / operating mode display.
7 Temperature level display.
Operating controls
Maintenance
In order to comply with applicable gas standards, the gas unit and ventilation ducts must be
checked by an authorized technical person at regular intervals, and a test certificate issued. It is
the user’s responsibility to arrange this test.
The gas burner must be inspected and cleaned as necessary, at least once a year.
Work on gas and electrical equipment shall be carried out by qualified personnel only.
This work can be carried out by the Auto-sleepers Service Centre at the annual habitation
service, or after an extended shutdown period.